Obtaining the UltraNet WebView Software
FTP WebView RPM File to Root Directory
Install the WebView Software
UltraNet WebView Monitoring Application
To verify the current version of WebView on your UltraNet Edge 3000, follow the procedure “Verify your Current Software Version”, found on page
NOTE: WebView has been tested on the following operating systems and browsers:
—Windows 98, NT, and 2000
—Internet Explorer 5.0, 5.5 and 6.0
Obtain the most current UltraNet WebView software release from McDATA Customer Support and install it on the Windows PC used to configure the network.
Use the following procedure to FTP the WebView software to the UltraNet Edge 3000 root directory.
1.Use the FTP protocol to download the software from your PC to the UltraNet Edge 3000.
2.FTP the UltraNet WebView software (.rpm file) from your PC to the root directory of the UltraNet Edge 3000.
The FTP client must be set for the transfer type of binary. The FTP client only requires a password if one was previously defined in the UltraNet Edge 3000.
Use the following procedure to install the new software:
1.Telnet into the UltraNet Edge 3000.
2.Enter the correct password if previously defined.
3.Issue the following command at the UltraNet Edge 3000 prompt: tm.0x10> upgrade
where: xx is the version of software you are upgrading to
example: tm.0x10> upgrade -w wv32.rpm
where: wv32 is WebView version 3.2
The software will be updated, the following is an example of the context that will appear:
upgrade
cfg envput _RPMCPUCheckDisabled YES
Product Support and Software Maintenance | |
|
|
11