D: Receive Data Word Allocation (4th Operand)

Receive data

+0

storage words

+1

 

 

+2

Number of receive data words

Response code

Receive data

Offset

Contents (data format)

Data

 

 

 

D+0

Number of receive data words

0003 to 0128 BCD

 

(4 digits BCD)

 

 

 

 

D+1

Response code (4 digits Hex)

The response code will be stored in

 

 

hexadecimal form.

 

 

 

D+2

Receive data (4-digit Hex)

The data from just after the response code

on

 

until just before the ETX will be converted

 

 

from ASCII to hexadecimal and stored here.

 

 

 

Standard System Protocols

 

The following 13 standard system protocols are provided with the CX-Protocol

 

and the Serial Communications Boards.

 

 

Protocol name

Function

 

 

CompoWay/F

Protocol for sending CompoWay/F commands as a Master to OMRON CompoWay/F slave

Master

components and receiving responses.

 

 

E5jK Digital

Protocol for controlling an E5jK Digital Controller via the Board. Procedures for reading the MV

Controller Read

the operating parameter settings

 

 

E5jK Digital

Protocol for controlling an E5jK Digital Controller via the Board. Procedures for writing set points

Controller Write

and operating parameters.

 

 

E5ZE Temperature

Protocol for controlling an E5ZE Temperature Controller via the Board. Procedures for reading

Controller Read

measured temperature and operating parameter settings.

 

 

E5ZE Temperature

Protocol for controlling an E5ZE Temperature Controller via the Board. Procedures for writing

Controller Write

control temperatures and operating parameters.

 

 

E5jJ Temperature

Protocol for controlling a E5jJ Temperature Controller via the Board. Procedures for writing set

Controller

points, reading output amounts, and reading/writing operating parameters.

 

 

ES100j Controller

Protocol for controlling an ES100j Controller via the Board. Procedures for writing adjustment

 

parameters, reading operation amounts, and writing/reading operating parameters.

 

 

Intelligent Signal

Protocol for controlling a Intelligent Signal Processor via the Board. Procedures for writing

Processor

comparison values and reading display values are set.

 

 

V500/V520 Bar

Protocol for controlling a Bar Code Reader via the Board. Procedures for controlling the Bar Code

Code Reader

Reader in remote mode, reading the data that has been read by the Bar Code Reader, and

 

reading/writing operating parameters.

 

 

3Z4L Laser

Protocol for controlling a Laser Micrometer via the Board. Procedures for controlling the Laser

Micrometer

Micrometer in remote mode, reading measured data, and writing/reading operating parameters.

F200/F300/F350

Protocol for controlling a Visual Inspection System via the Board. Procedures for controlling the

Visual Inspection

Visual Inspection System in remote mode, reading measured values, and writing/reading

Systems

operating parameters.

 

 

V600/V620 ID

Protocol for controlling an ID Controller via the Board. Procedures for performing Read/Write

Controllers

operations of the ID Controller and writing/reading operating parameters.

Hayes modem AT

Protocol for controlling a Hayes modem (AT commands) via the Board. Procedures for initialization

commands

of the modem, dialing, data transmission, switching to escape mode, and disconnecting the line.

Note Some of the standard system protocols do not allow communications with 32 nodes for one execution of a sequence (for 1:N connections). For example, it’s not possible when the number of Units in send data is 1 to 25 for unit numbers 00 to 31 (e.g., in the temperature controller read sequences). This restriction is due to a limit in the number of words that can be transferred between the CPU Unit and the Serial Communications Board. These sequences, however, allow the unit numbers of connected devices to be specified in the send data. You can thus set different unit numbers in the send data and execute PMCR(––) for the same se- quence as many times as required for all unit numbers.