Appendix I

K3Tj Intelligent Signal Processor Protocol

The K3Tj Intelligent Signal Processor Protocol is used to make various settings or control remotely the Intelligent Signal Processor connected to the Serial Communications Board via RS-232C or RS-422A/485 cable.

Protocol Configuration

The configuration of the K3Tj Intelligent Signal Processor Protocol is shown as follows:

Sequence

Communications

Function

Ladder interface

Notes

No.

sequence name

 

 

 

 

 

Send word

Receive word

 

 

 

 

 

 

 

 

allocation

allocation

 

 

 

 

 

 

 

300

Reset (by unit number)

Performs the same processing as

Yes

No

 

 

 

when an input is received on the

 

 

 

 

 

reset terminal.

 

 

 

 

 

 

 

 

 

301

Reset (continuous units)

Performs the same processing as

Yes

No

 

 

 

when an input is received on the

 

 

 

 

 

reset terminal.

 

 

 

 

 

 

 

 

 

302

Write set value (by unit

Writes the set value HH, H, L, or

Yes

No

See

 

number)

LL.

 

 

Note1

 

 

 

 

 

 

303

Write set value HH (con-

Writes the set value HH.

Yes

No

See

 

tinuous units)

 

 

 

Note1

 

 

 

 

 

 

304

Write set value H (con-

Writes the set value H.

Yes

No

See

 

tinuous units)

 

 

 

Note1

 

 

 

 

 

 

305

Write set value L (contin-

Writes the set value L.

Yes

No

See

 

uous units)

 

 

 

Note1

 

 

 

 

 

 

306

Write set value LL (con-

Writes the set value LL.

Yes

No

See

 

tinuous units)

 

 

 

Note1

307

Write set value with bank

Writes the set value to a bank

Yes

No

See

 

(by unit number)

which is not in use (K3TR: HH to

 

 

Note2

 

 

LL, K3TC: O1 to O5).

 

 

 

 

 

 

 

 

 

308

Write set value HH with

Writes the set value HH to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

309

Write set value H with

Writes the set value H to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

310

Write set value L with

Writes the set value L to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

311

Write set value LL with

Writes the set value LL to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

312

Write set value O5 with

Writes the set value O5 to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

313

Write set value O4 with

Writes the set value O4 to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

314

Write set value O3 with

Writes the set value O3 to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

315

Write set value O2 with

Writes the set value O2 to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

316

Write set value O1 with

Writes the set value O1 to a bank

Yes

No

See

 

bank (continuous units)

which is not in use.

 

 

Note1

 

 

 

 

 

 

317

Read set value (by unit

Reads the set value HH, H, L, or

Yes

Yes

See

 

number)

LL.

 

 

Note1

 

 

 

 

 

 

318

Read set value HH (con-

Reads the set value HH.

Yes

Yes

See

 

tinuous units)

 

 

 

Note1

 

 

 

 

 

 

319

Read set value H (con-

Reads the set value H.

Yes

Yes

See

 

tinuous units)

 

 

 

Note1