E5jK Digital Controller Write Protocol

Appendix D

 

 

 

General-purpose Write (Sequence No. 070)

Writes the specified parameter.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Unit No.

 

 

 

 

 

 

+2

(Undefined)

Parameter No.

 

 

 

 

 

+3

Write data

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0004 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 31

 

 

 

+2

Parameter No. (2 digits BCD)

Refer to the manual of E5jK.

 

 

 

+3

Write data (4 digits BCD)

0000 to 9999

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note To write parameters in the setup mode or extended mode, execute Switch to Level 1 (Sequence No. 075) in advance.

Switch to Level 0 (Software Reset) (Sequence No. 071)

Resets the operation of the E5jK and waits until communications are enabled. This sequence can be executed for multiple units.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

 

Number of send data words

 

send data

 

 

 

 

 

+1

 

Number of units

 

 

 

 

 

 

 

 

 

 

 

+2

 

(Undefined)

Unit No.

 

 

 

 

 

 

 

 

 

 

 

+3

 

(Undefined)

Unit No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

 

~

+9

(Undefined)

Unit No.

(max.)

Offset

Contents (data format)

Data

+0

Number of send data words

Number of units + 2

 

(4 digits BCD)

 

+1

Number of units

0001 to 0008

 

(4 digits BCD)

 

+2 to 9

Unit No.

00 to 31

 

(2 digits BCD)

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note When this sequence is executed, a software reset command is issued and the operation of the E5jK is reset (equivalent to turning on the power supply). About five seconds will be required until communications are enabled.

182

Page 189
Image 189
Omron CQM1H-SCB41 operation manual General-purpose Write Sequence No, Switch to Level 0 Software Reset Sequence No