Visual Inspection System Protocol

Appendix L

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data storage words

+0

 

Number of receive data words

 

 

 

 

 

 

 

+1

 

(Undefined)

 

Window No.

 

 

 

 

 

 

 

 

+2

 

 

(Undefined)

Evaluation

 

 

 

result

 

 

 

 

 

 

 

 

+3

 

 

 

 

Decimal portion

 

 

 

 

 

 

 

 

 

+4

 

 

 

Integer portion

 

 

 

 

 

 

 

 

 

 

 

+5

 

Sign

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

+6

 

 

 

 

Decimal portion

 

 

 

 

 

 

 

 

 

+7

 

 

 

Integer portion

 

 

 

 

 

 

 

 

 

 

 

+8

 

Sign

 

0

 

 

 

 

 

 

 

 

 

 

 

 

+9

 

 

 

 

Decimal portion

 

 

 

 

 

 

 

 

 

+10

 

 

 

Integer portion

 

 

 

 

 

 

 

 

 

 

 

+11

 

Sign

 

0

 

 

 

 

 

 

 

 

 

 

 

 

+12

 

 

 

 

Decimal portion

 

+13

 

 

 

Integer portion

 

 

+14

 

Sign

 

0

 

 

 

 

+15

 

 

 

 

Decimal portion

 

+16

 

 

 

Integer portion

 

 

+17

 

Sign

 

0

 

 

 

 

Data 1

Data 2

Data 3

Data 4

Data 5

Offset

Content (data format)

 

 

 

 

Data

 

 

 

 

 

 

 

 

 

 

 

+0

Number of receive data words

0006:

1 measurement item

 

 

 

(4 digits BCD)

0009:

2 measurement items

 

 

 

 

0012:

3 measurement items

 

 

0015:

4 measurement items

 

 

0018:

5 measurement items

 

 

 

 

 

 

 

 

 

+1

Window No. (2 digits BCD)

00 to 07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

Evaluation result (1 digit BCD)

0:

OK

 

 

 

 

 

 

 

 

1:

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+3 to

Measurement value (decimal portion)

Example

Example

+5

(3 digits BCD)

–123.456

+123.456

 

 

 

 

 

 

 

 

 

 

 

 

 

+3

 

3456

 

+3

 

3456

 

 

Measurement value (integer portion)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(7 digits BCD)

+4

 

0012

 

+4

 

0012

 

 

 

+5

 

 

 

+5

 

 

 

 

 

 

F000

 

 

0000

 

 

Measurement value (sign)

 

 

 

 

 

 

 

 

 

 

 

 

 

(1 digit)

 

F is stored for negative values.

 

 

 

 

 

 

 

 

 

 

+6 to

Same as +3 to +5.

Same as +3 to +5.

 

 

 

 

+8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+9 to

Same as +3 to +5.

Same as +3 to +5.

 

 

 

 

+11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12 to

Same as +3 to +5.

Same as +3 to +5.

 

 

 

 

+14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+15 to

Same as +3 to +5.

Same as +3 to +5.

 

 

 

 

+17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. Exponential expressions are used for numbers larger than 9999999.999 and smaller than –999999.9.

2.The number of measurement items are up to 5, but only one window number can be read.

3.The range of measurement values are as follows:

For calibration OFF setting : –2147483.648 to 2147483.648

For calibration ON setting : –9999999.999 to 9999999.999

4.The priority order of measurement items being output are as follows: Area

Center of gravity X, Center of gravity Y

Displacement in center of gravity X (reserved), displacement in center of gravity Y (reserved) Main axis angle

358

Page 361