V600/V620 ID Controller Protocol

 

Appendix M

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of send data words

0006 to 0129

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Relevant Unit No. (2 digits BCD)

00 to 07 (CD1D)

 

 

 

 

 

00 to 15 (CA2A)

 

 

 

 

 

 

 

 

+2

R/W Head CH No. (1 digit BCD)

R/W Head CH 1 designation: 1

 

 

 

 

 

R/W Head CH 2 designation: 2

 

 

 

 

 

The CD1D must be set to 1.

 

 

 

 

 

 

 

 

+3

Leading address No.

0000 to FFFF

 

 

 

 

(4 digits Hexadecimal)

 

 

 

 

 

 

 

 

 

+4

Number of write bytes

0001 to 0248

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+5to

Write data (ASCII)

Input in ASCII

 

 

+128

 

Up to 248 bytes (max.) can be set

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note Write data designated for ASCII is sent beginning with the smallest offset from the send data words.

Write (ASCII/2) (Sequence No. 519)

This sequence is used when the number of Heads to be written to the Carrier is 2. Up to 118 bytes of data can be read for each Read/Write Head.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data+1

+2

+3

+4

+5

+6

~

+64

+65

+66

+67

+68

+69

+70

~

+128

Number of send data words

Number of Heads

(Undefined)

 

Unit No.

(Undefined)

 

Head CH No.

 

 

 

 

Leading address No.

Number of write bytes

Write data

~

Write data

(Not used)

(Undefined)

 

Unit No.

(Undefined)

 

Head CH No.

 

 

 

 

Leading address No.

Number of write bytes

Write data

~

Write data

CH 1

CH 2

387

Page 390
Image 390
Omron CQM1H-SCB41 operation manual Write ASCII/2 Sequence No, Appendix M