ES100j Digital Controller Protocol

 

Appendix H

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

+0

Number of send data words

0058 (fixed)

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 31

 

 

 

 

 

 

 

 

 

+2 to 3

PID No. 1 P (8 digits BCD)

00000000 to 09999000

 

 

 

 

 

 

 

 

 

+4 to 5

PID No. 1 I (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+6 to 7

PID No. 1 D (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+8 to 9

PID No. 1 MV lower limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+10 to 11

PID No. 1 MV upper limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+12 to 13

PID No. 1 PV bias value

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+14 to 15

PID No. 1 Automatic selection range

 

 

 

 

 

upper limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

D

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

+44 to 45

PID No. 4 P (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+46 to 47

PID No. 4 I (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+48 to 49

PID No. 4 D (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+50 to 51

PID No. 4 MV lower limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+52 to 53

PID No. 4 MV upper limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+54 to 55

PID No. 4 PV bias value

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+56 to 57

PID No. 4 Automatic selection range

 

 

 

 

 

upper limit

 

 

 

 

 

(8 digits BCD)

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

265

Page 270
Image 270