K3Tj Intelligent Signal Processor Protocol

Appendix I

 

 

 

Read Display Value (PV) (Continuous Units) (Sequence No. 336)

This sequence reads display value (PV) for continuous units.

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

Number of send data words

send data

 

 

 

+1

(Undefined)

Number of units

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0002

 

(4 digits BCD)

 

 

 

 

+1

Number of units

01 to 32

 

(2 digits BCD)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

This sequence is similar to sequence No. 335 (Read Display Value (PV) (Continuous Units)).

Model Data Read (by Unit Number) (Sequence No. 337)

Reads model data and stores the results in the specified words.

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

send data

+1

+2

Number of send data words

(Undefined)

Number of units

 

 

(Undefined)

Relevant unit No.

 

 

~

 

 

~

 

 

 

 

 

 

 

 

+26

 

(Undefined)

Relevant unit No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

 

Data

 

 

 

 

 

 

 

 

 

+0

Number of send data words

 

 

0003 to 0027

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+1

Number of units

 

 

01 to 25

 

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+2

Relevant unit No.

 

 

00 to 99

 

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

+ 26

Relevant unit No.

 

 

Same as above

 

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

Note The number of Units can be up to 25 maximum.

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

 

Number of receive data words

storage words

 

 

 

 

+1

 

Input specifications

 

 

 

 

 

 

 

 

+2

 

Input specifications

Display specifications

 

 

 

 

 

 

+3

 

Output specifications

 

+4

 

Input contents

 

 

 

+5

 

Operation mode

 

 

 

 

 

~

 

~

 

 

 

 

 

 

+121

 

Input specifications

 

 

 

 

 

 

+122

 

Input specifications

Display specifications

 

 

 

 

 

 

+123

 

Output specifications

 

+124

 

Input contents

 

+125

 

Operation mode

 

 

 

 

301

Page 306
Image 306
Omron CQM1H-SCB41 Read Display Value PV Continuous Units Sequence No, Model Data Read by Unit Number Sequence No