Appendix K

3Z4L Laser Micrometer Protocol

The 3Z4L Laser Micrometer Protocol is used to make various settings or control remotely the Laser Micrometer connected to the Serial Communications Board via RS-232C cable.

Protocol Configuration

The configuration of the 3Z4L Laser Micrometer Protocol is shown below.

Sequence

Communications sequence

Function

Ladder interface

No.

name

 

 

 

 

Send word

Receive

 

 

 

 

 

 

allocation

word

 

 

 

 

allocation

 

 

 

 

 

400

3Z4L clear

Resets errors, data, analog output, deci-

No

No

 

 

sion result and places the Laser Microme-

 

 

 

 

ter into standby.

 

 

 

 

 

 

 

401

Memory switch set

Sets memory switches and the area for

Yes

No

 

 

the work position LED.

 

 

 

 

 

 

 

402

mm unit set

Sets the display unit to mm.

No

No

 

 

 

 

 

403

E unit set

Sets the display unit to E.

No

No

 

 

 

 

 

404

Calibration set

Calibrates the Laser Micrometer.

Yes

No

 

 

Calibration setting release.

 

 

 

 

 

 

 

405

Calibration release

Releases the calibration of the Laser Mi-

No

No

 

 

crometer.

 

 

 

 

 

 

 

406

Program number set

Switches the program number to a speci-

Yes

No

 

(3000-series)

fied number.

 

 

 

 

 

 

 

407

Measurement condition set

Sets measurement conditions.

Yes

No

 

(3000-series)

 

 

 

 

 

 

 

 

408

Measurement condition re-

Releases measurement conditions that

Yes

No

 

lease (3000-series)

have been set.

 

 

 

 

 

 

 

409

Measurement condition list re-

Requests the measurement conditions

No

Yes

 

quest (3000-series)

that have been set and other settings.

 

 

410

Single run measurement start

When the sample measurement condition

No

Yes

 

(3000-series)

is from 1 to 999, performs a single run

 

 

 

 

measurement and requests the measure-

 

 

 

 

ment results.

 

 

 

 

 

 

 

411

Zero run measurement start

If the sample measurement condition is

No

No

 

(3000-series)

zero, starts a zero run measurement.

 

 

412

Continuous measurement

Starts a continuous measurement. The

No

Yes

 

start (scan) (3000-series)

scan notification method is used for re-

 

 

 

 

ceive data.

 

 

 

 

 

 

 

413

Continuous measurement

Starts a continuous measurement. The

No

Yes

 

start (interrupt) (3000-series)

interrupt notification method is used for

 

 

 

 

receive data.

 

 

 

 

Measurement termination (3000-series)

 

 

 

 

 

 

 

414

Measurement termination

Terminates a continuous measurement.

No

No*1

 

(3000-series)

 

 

 

 

 

 

 

 

415

Data request (3000-series)

Requests display data in the idle mea-

No

Yes

 

 

surement status or the latch data gener-

 

 

 

 

ated by the measurement command.

 

 

 

 

 

 

 

416

Statistic processing execution

Lights the statistic processing LED and

No

No

 

(3000-series)

processes the statistics.

 

 

 

 

 

 

 

417

Statistic processing non-

Turns OFF the statistic processing LED.

No

No

 

execution (3000-series)

Statistics are not processed.

 

 

317