Appendix L

Visual Inspection System Protocol

The Visual Inspection System Protocol is used to make various settings or control remotely the Visual Recognition Device connected to the Serial Communications Board via RS-232C cable.

Protocol Configuration

The configuration of the Visual Inspection System Protocol is shown below.

Sequence

Communications

Function

Ladder interface

No.

sequence name

 

 

 

 

Send word

Receive word

 

 

 

 

 

 

allocation

allocation

450

Measurement execution

Carries out one measurement one and

No

Yes

 

(F200)

stores the measurement results in the

 

 

 

 

specified words.

 

 

 

 

 

 

 

451

Continuous measure-

Carries out continuously setting the F200

No

Yes

 

ment execution (scan)

and storing the measurement results in

 

 

 

(F200)

the specified words.

 

 

 

 

 

 

 

452

Continuous measure-

Carries out continuously setting the F200

No

Yes

 

ment execution (inter-

and storing the measurement results in

 

 

 

rupt) (F200)

the specified words.

 

 

 

 

 

 

 

453

Reference object regis-

Performs reference position registration

No

No

 

tration (group) (F200)

and evaluation criterion registration at the

 

 

 

 

same time.

 

 

 

 

 

 

 

454

Reference object regis-

Registers the reference position for mea-

No

No

 

tration (reference posi-

suring the amount of position displace-

 

 

 

tion) (F200)

ment when a position displacement com-

 

 

 

 

pensation is used.

 

 

 

 

 

 

 

455

Reference object regis-

Registers the reference value to discrimi-

No

No

 

tration (evaluation criteri-

nate the output format.

 

 

 

on) (F200)

 

 

 

 

 

 

 

 

456

Evaluation condition

Changes the upper and lower limit values

Yes

No

 

change (F200)

of the evaluation condition of the desig-

 

 

 

 

nated output No.

 

 

 

 

 

 

 

457

Arbitrary measurement

Stores the measurement values of arbi-

Yes

Yes

 

value acquisition (F200)

trary measurement item regardless of out-

 

 

 

 

put format in the specified words.

 

 

 

 

 

 

 

460

Measurement execution

Carries out one measurement and stores

No

Yes

 

(F300)

the measurement results in the specified

 

 

 

 

words.

 

 

 

 

 

 

 

461

Continuous measure-

Carries out continuously setting the F300

No

Yes

 

ment execution (scan)

and storing the measurement results in

 

 

 

(F300)

the specified words.

 

 

 

 

 

 

 

462

Continuous measure-

Carries out continuously setting the F300

No

Yes

 

ment execution (inter-

and storing the measurement results in

 

 

 

rupt) (F300)

the specified words.

 

 

 

 

 

 

 

463

Reference object regis-

Performs a measurement for the input

No

No

 

tration command 1

image and updates the reference object

 

 

 

execution (F300)

data of the full window.

 

 

 

 

 

 

 

464

Reference object regis-

Performs a measurement for the input

Yes

No

 

tration command 2

image and updates the reference object

 

 

 

execution (F300)

data of the full window

 

 

 

 

 

 

 

465

Illumination fluctuation

Executes an illumination fluctuation follow.

No

No

 

follow execution (F300)

 

 

 

 

 

 

 

 

470

Measurement execution

Carries out one measurement and stores

No

Yes

 

and positioning (F350)

the measurement results in the specified

 

 

 

 

words.

 

 

349

Page 352
Image 352
Omron CQM1H-SCB41 operation manual Appendix L, Visual Inspection System Protocol