Appendix H

 

ES100j Digital Controller Protocol

The

ES100j Digital Controller Protocol controls in remote mode and reads various settings from the Controller

connected to the Serial Communications Board via RS-232C or RS-422A/485 cable.

Note

Negative values cannot be written. All values must be set as unsigned BCD.

Structure of the Protocol

The structure of the ES100j Digital Controller Protocol is shown below.

Sequence

Transmission

Function

Ladder interface

No.

sequence name

 

 

 

 

Send word

Receive word

 

 

 

 

 

 

allocation

allocation

 

 

 

 

 

250

Read event data

Reads events 1 to 10 in the variable area.

Yes

Yes

 

 

 

 

 

251

Read time signals

Reads time signals 1 to 10 in the variable

Yes

Yes

 

 

area.

 

 

 

 

 

 

 

252

Read error detection

Reads error groups 1 to 15 in the variable

Yes

Yes

 

data

area.

 

 

253

Read heater burnout

Reads the heater burnout alarm.

Yes

Yes

 

data

 

 

 

254

Read PV data

Reads PV data in the variable area.

Yes

Yes

 

 

 

 

 

255

Read SP data

Reads SP data in the variable area.

Yes

Yes

 

 

 

 

 

256

Read MV

Reads the MV in the variable area.

Yes

Yes

 

 

 

 

 

257

Read control monitor

Reads control monitor data (SP, PV, and MV)

Yes

Yes

 

data

in the variable area.

 

 

 

 

 

 

 

258

Read adjustment pa-

Reads adjustment parameters in the param-

Yes

Yes

 

rameters

eter area.

 

 

 

 

 

 

 

259

Write adjustment pa-

Writes adjustment parameters in the param-

Yes

No

 

rameters

eter area.

 

 

260

Read PID control pa-

Reads PID parameters No. 1 to 4 from the

Yes

Yes

 

rameters 1

PID control parameters in the parameter

 

 

 

 

area.

 

 

 

 

 

 

 

261

Read PID control pa-

Reads PID parameters No. 5 to 8 from the

Yes

Yes

 

rameters 2

PID control parameters in the parameter

 

 

 

 

area.

 

 

 

 

 

 

 

262

Write PID control pa-

Writes PID parameters No. 1 to 4 from PID

Yes

No

 

rameters 1

control parameters in the parameter area.

 

 

263

Write PID control pa-

Writes PID parameters No. 5 to 8 from PID

Yes

No

 

rameters 2

control parameters in the parameter area.

 

 

 

 

 

 

 

264

Read local SP

Reads the local SP in the program parame-

Yes

Yes

 

 

ter area.

 

 

 

 

 

 

 

265

Write local SP

Writes local SP in the program parameter

Yes

No

 

 

area.

 

 

 

 

 

 

 

266

Read program param-

Reads local SP, step time, PID No. wait

Yes

Yes

 

eters

code, and events 1 to 10 set values in the

 

 

 

 

program parameter area.

 

 

 

 

 

 

 

267

Write program parame-

Writes the local SP, step time, PID No., wait

Yes

No

 

ters

code, and event 1 to 10 set values in the

 

 

 

 

program parameter area.

 

 

 

 

 

 

 

268

Remote setting mode

Switches the setting mode to remote setting.

Yes

No

 

 

 

 

 

269

Local setting mode

Switches the setting mode to local setting.

Yes

No

 

 

 

 

 

270

External setting mode

Switches the setting mode to external set-

Yes

No

 

 

ting.

 

 

 

 

 

 

 

271

Run command

Starts control.

Yes

No

 

 

 

 

 

272

Reset (stop)

Stops control.

Yes

No

243

Page 248
Image 248
Omron CQM1H-SCB41 operation manual Appendix H, ES100j Digital Controller Protocol