Appendix C

E5jK Digital Controller Read Protocol

The E5jK Digital Controller Read Protocol reads and controls various parameters in remote mode for the Con- troller connected to the Serial Communications Board via RS-232C or RS-485 cable.

Structure of the Protocol

The following table shows the structure of the E5jK Digital Controller Read Protocol.

Sequence

Communications sequence

Function

 

Ladder interface

No.

name

 

 

 

 

 

 

 

 

Send word

Receive word

 

 

 

 

 

 

 

 

 

 

allocation

allocation

000

Read process value

 

Reads the process value.

 

Yes

Yes

 

 

 

 

 

 

001

Read set point during SP ramp

Reads the set point during SP

 

Yes

Yes

 

 

 

ramp.

 

 

 

 

 

 

 

 

 

 

002

Read MV

 

Reads the MV (heating, cooling).

 

Yes

Yes

 

 

 

 

 

 

 

003

Read set point

 

Reads the set point.

 

Yes

Yes

 

 

 

 

 

 

 

004

Read alarm value

 

Reads alarm value 1, 2.

 

Yes

Yes

 

 

 

 

 

 

005

Read proportional band, integral

Reads the proportional band, inte-

 

Yes

Yes

 

time, and derivative time

 

gral (reset) time, and derivative

 

 

 

 

 

 

(rate) time

 

 

 

 

 

 

 

 

 

 

006

Read cooling coefficient

 

Reads the cooling coefficient.

 

Yes

Yes

 

 

 

 

 

 

 

007

Read dead band

 

Reads the dead band.

 

Yes

Yes

 

 

 

 

 

 

 

008

Read manual reset value

 

Reads the manual reset value.

 

Yes

Yes

 

 

 

 

 

 

 

009

Read hysteresis

 

Reads the hysteresis (heating,

 

Yes

Yes

 

 

 

cooling).

 

 

 

010

Read control period

 

Reads the control period (heating,

 

Yes

Yes

 

 

 

cooling).

 

 

 

011

Read SP ramp time unit and set

Reads the SP ramp time unit and

 

Yes

Yes

 

value

 

SP ramp set value.

 

 

 

 

 

 

 

 

 

 

012

Read LBA detection time

 

Reads the LBA detection time.

 

Yes

Yes

 

 

 

 

 

 

 

013

Read MV at stop and PV error

 

Reads the MV at stop and the MV

 

Yes

Yes

 

 

 

at PV error.

 

 

 

 

 

 

 

 

 

 

014

Read MV limits

 

Reads the MV limits.

 

Yes

Yes

 

 

 

 

 

 

 

015

Read input digital filter

 

Reads the input digital filter.

 

Yes

Yes

 

 

 

 

 

 

 

016

Read alarm hysteresis

 

Reads the alarm 1, 2 hysteresis.

 

Yes

Yes

 

 

 

 

 

 

 

017

Read input shifts

 

Reads the input shift limits.

 

Yes

Yes

 

 

 

 

 

 

 

018

Read level 0 parameters

 

Reads parameters in level 0.

 

Yes

Yes

 

 

 

 

 

 

 

019

Read level 1 parameters 1

 

Reads parameters in level 1.

 

Yes

Yes

 

 

 

 

 

 

 

020

Read level 1 parameters 2

 

Reads parameters in level 1.

 

Yes

Yes

 

 

 

 

 

 

 

021

Read level 2 parameters 1

 

Reads parameters in level 2.

 

Yes

Yes

 

 

 

 

 

 

 

022

Read level 2 parameters 2

 

Reads parameters in level 2.

 

Yes

Yes

 

 

 

 

 

 

 

023

General-purpose read

 

Reads the value of the specified

 

Yes

Yes

 

 

 

parameter.

 

 

 

Note Ladder Interface Settings

 

 

 

 

 

YES:

User settings are required for the 2nd or 3rd operands of PMCR.

 

 

NO:

Send word allocation:

Set the constant 0000 for the 2nd operand (S).

 

 

Receive word allocation: Set a dummy word (e.g., DM 0000) address for the 3rd operand (D).

153

Page 160
Image 160
Omron CQM1H-SCB41 operation manual Appendix C, E5jK Digital Controller Read Protocol