Omron CQM1H-SCB41 operation manual Write Hexadecimal/1 Sequence No

Models: CQM1H-SCB41

1 421
Download 421 pages 6 Kb
Page 394
Image 394
Unit No.

V600/V620 ID Controller Protocol

Appendix M

 

 

 

Write (Hexadecimal/1) (Sequence No. 522)

This sequence is used when the number of Heads to be written to the Carrier is 1.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data+1

+2

+3

+4

+5

~

Number of send data words

(Undefined)

(Undefined)

Head CH No.

 

 

Leading address No.

Number of write digits

Write data

~

Max +35

(Undefined)

Write data

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0006 to 0036

 

(4 digits BCD)

 

 

 

 

+1

Relevant Unit No. (2 digits BCD)

00 to 07 (CD1D)

 

 

00 to 15 (CA2A)

 

 

 

+2

R/W Head CH No. (1 digit BCD)

R/W Head CH 1 designation: 1

 

 

R/W Head CH 2 designation: 2

 

 

The CD1D must be set to 1.

 

 

 

+3

Leading address No.

0000 to FFFF

 

(4 digits Hexadecimal)

 

 

 

 

+4

Number of write digits

0002 to 0122

 

(4 digits BCD)

 

 

 

 

+5 to

Write data (Hexadecimal)

Input in hexadecimal

35

 

Up to 122 digits (max.)

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. Data of which Data Carrier designated for hexadecimal is sent beginning with the largest offset from the send data words.

2. Always set an even number of digits for the write data.