Using Protocol Macros

Section 5-3

Note The PC Setup settings for the Serial Communications Board are read constantly during PC operation. It is not necessary to restart the PC after changing these settings.

The default settings are shown in the following table. These are the standard settings for protocol macros.

Port 1

Port 2

Bit(s)

Setting

Function

 

 

 

 

 

DM 6555

DM 6550

00 to 03

0 Hex

Standard port settings (1 start bit,

 

 

 

 

7-bit data, even parity, 2 stop bits,

 

 

 

 

9,600 bps)

 

 

 

 

 

 

 

04 to 07

---

Not used.

 

 

 

 

 

 

 

08 to 11

---

Not used.

 

 

 

 

 

 

 

12 to 15

6 Hex

Communications mode:

 

 

 

 

Protocol macro

DM 6556

DM 6551

00 to 07

---

Baud rate setting disabled.

 

 

 

 

 

 

 

08 to 15

---

Frame format setting disabled.

 

 

 

 

 

DM 6557

DM 6552

00 to 15

---

Not used.

 

 

 

 

 

DM 6558

DM 6553

00 to 15

---

Not used.

 

 

 

 

 

DM 6559

DM 6554

00 to 15

---

Not used.

6.Run the system as described below in Using Standard System Protocols or in Using User-created Protocols.

Using Standard System Protocols

 

Executed

CPU Unit

with

PMCR(––)

Uses standard system protocol No. 600

External device

Example: K3N Series

Serial CommunicationsDigital Panel Meter

Board

1, 2, 3... 1. Setting the Send Data

Refer to information on the 2nd operand of PMCR(––) in Appendix B Com- poWay/F Master Protocol and set the number of send data words in S, and set the send data starting in S+1.

2.Coding PMCR(––)

The following example shows how to use a Serial Communications Board to read the present value for a K3N-series Digital Panel Meter using the Com- poWay/F Master standard system protocol sequence No. 600: Send/Re- ceive with ASCII Conversion and Response.

 

Protocol Macro

Input condition

Executing Flag

PMCR

#1600

DM0000

DM1000

1:Use port 1, 600: Sequence No. 600 First word of send data

First storage word for receive data

If the input condition turns ON when the Protocol Macro Executing Flag (IR 20708 for Port 1) is OFF, communications sequence No. 600 of the stan- dard system protocol in the Serial Communications Board is called, and data is sent and received via port 1 of the Serial Communications Board.

67