Omron CQM1H-SCB41 operation manual Read ASCII/2 Sequence No

Models: CQM1H-SCB41

1 421
Download 421 pages 6 Kb
Page 378
Image 378

V600/V620 ID Controller Protocol

Appendix M

 

 

 

Read (ASCII/2) (Sequence No. 501)

This sequence is used when the number of Heads to be read from the Carrier is 2. Up to 118 bytes of data can be read for each Read/Write Head.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data+1

+2

+3

+4

+5

+6

+7

+8

+9

Number of send data words

Number of Heads

(Undefined)

 

Unit No.

 

 

 

(Undefined)

 

Head CH No.

 

 

Leading address No.

 

 

(Undefined)

Read bytes

 

 

 

(Undefined)

 

Unit No.

 

 

 

(Undefined)

 

Head CH No.

 

 

Leading address No.

 

 

(Undefined)

Read bytes

 

 

 

CH 1

CH 2

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0006 to 0010

 

(4 digits BCD)

 

 

 

 

+1

Number of Heads

0001 to 0002

 

(4 digits BCD)

 

 

 

 

+(4(N–1)+2)

Unit No. (2 digits BCD)

Arbitrary (However, there is a limit for the

 

 

maximum Unit No. depending on the model)

 

 

 

+(4(N–1)+3)

R/W Head CH No.

R/W Head CH 1 designation: 1

 

(1 digit BCD)

R/W Head CH 2 designation: 2

 

 

 

 

The CD1D must be set to 1.

 

 

 

+(4(N–1)+4)

Leading address No.

0000 to FFFF

 

(4 digits Hexadecimal)

 

 

 

 

+(4(N–1)+5)

Read bytes

01 to 76 (1 to 118 bytes)

 

(2 digits Hexadecimal)

 

 

 

 

N: Number of Heads

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

 

Number of receive data words

 

 

storage words

+1

 

Read data

 

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

 

+59

 

Read data

 

 

 

 

 

 

 

+60

 

Not used

 

 

 

 

 

+61

 

Read data

 

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

 

+119

 

Read data

 

CH 1

CH 2

Offset

Contents (data format)

Data

 

 

 

+0

Number of receive data

0002 to 0120

 

words (4 digits BCD)

 

 

 

 

+(60(N–1)+1) to

Read data (ASCII)

Number of read bytes store in ASCII

+(60(N–1)+59)

 

 

 

 

 

N: Number of Heads

 

Note Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the receive data words.

375

Page 378
Image 378