V600/V620 ID Controller Protocol

 

Appendix M

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of send data words

0007 to 0129

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Number of Heads

0001 to 0002

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+(64(N–1)+2)

Unit No. (2 digits BCD)

Arbitrary (However, there is a limit for the

 

 

 

 

 

maximum Unit No. depending on the model)

 

 

 

 

 

 

 

 

 

+(64(N–1)+3)

R/W Head CH No.

R/W Head CH 1 designation: 1

 

 

 

 

(1 digit BCD)

R/W Head CH 2 designation: 2

 

 

 

 

 

 

 

 

 

 

The CD1D must be set to 1.

 

 

 

 

 

 

 

 

 

+(64(N–1)+4)

Leading address No.

0000 to FFFF

 

 

 

 

(4 digits Hexadecimal)

 

 

 

 

 

 

 

 

 

 

+(64(N–1)+5)

Number of write bytes

0001 to 0118

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+(64(N–1)+6) to

Write data (ASCII)

Input in ASCII.

 

 

 

(64(N–1)+64)

 

Up to 118 bytes (max.) can be set

 

 

 

 

 

 

 

 

N: Number of Heads

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note Write data designated for ASCII is sent beginning with the smallest offset from the send data words.

388

Page 391
Image 391
Omron CQM1H-SCB41 operation manual 388