3Z4L Laser Micrometer Protocol

 

 

 

 

 

Appendix K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

 

+0

Number of send data words

0025 (fixed)

 

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1

Segment number

1 to 5

 

 

 

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

Measurement interval

1 to 7

 

 

 

 

 

 

 

 

 

number (1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+3

Lower limit value (Decimal

0000 to 9999

 

Example –123.4567

 

 

 

 

portion)

 

 

 

 

 

 

 

 

 

 

(4 digits BCD)

 

 

 

+3

4 5 6 7

 

 

 

 

 

 

 

 

 

 

 

 

 

+4

Lower limit value (integer

000 to 999

 

+4

0 1 2 3

 

 

 

 

 

portion) (3 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+5

2 D 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

+5

Lower limit value (Sign)

If +:

20 (‘ ’)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(ASCII 1 character)

If – :

2D (‘–’)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+6 to

Upper limit value

Same as lower limit value

 

 

 

 

 

+8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+9 to

Reference value

Same as lower limit value

 

 

 

 

 

+11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12

Analog output scale number

0 to 3

 

 

 

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+13 to

Unused

 

 

 

 

 

 

 

 

+15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+16

Data output conditions

0 to 6

 

 

 

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+17

Data output timer value

000 to 999

 

 

 

 

 

 

 

(3 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+18

Number of seconds for latch

00 to 99

 

 

 

 

 

 

 

timer

 

 

 

 

 

 

 

 

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+19

Yes/No for segment setting

Set:

1(SG)

 

 

 

 

 

 

 

(1 digit BCD)

Don’t set: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+20

Yes/No for measurement

Set:

1(M)

 

 

 

 

 

 

 

interval number setting

Don’t set: 0

 

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+21

Yes/No for upper/lower limit

Set:

1(LL, LH)

 

 

 

 

 

 

 

value setting

Don’t set: 0

 

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+22

Yes/No for reference setting

Set:

1(REF, SCL)

 

 

 

 

 

 

 

(1 digit BCD)

Don’t set: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+23

Yes/No for data output

Set:

1(PR, PRT)

 

 

 

 

 

 

 

condition setting

Don’t set: 0

 

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+24

Yes/No for latch timer

Set:

1(RLT)

 

 

 

 

 

 

 

setting (1 digit BCD)

Don’t set: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. The following settings must be made together with this sequence; they cannot be set separately. Lower limit, upper limit

Reference value, data output timer

Data output conditions, scheduled print timer

2.The limit value and reference value can be set to 3 digits for the integer portion and to 4 digits for the decimal portion.

341