E5ZE Temperature Controller Write Protocol

Appendix F

 

 

 

Cancel Autotuning (Sequence No. 160)

Cancels Autotuning (AT) for all channels.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Unit No.

 

 

 

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

+0

Number of send data words

0002

(fixed)

 

(4 digits BCD)

 

 

 

 

 

 

+1

Unit No. (2 digits Hex)

00 to

0F

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Write Setting Unit (Sequence No. 161)

Writes the setting unit.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

 

+1

(Undefined)

 

Unit No.

 

 

 

 

 

 

 

 

+2

Write code

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0003 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits Hex)

00 to 0F

 

 

 

+2

Write code (4 digits BCD)

0000: unit of 1

 

 

0001: unit of 0.1

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Write Input Shift Value (Sequence No. 162)

Writes the input shift values.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

send data

+1

 

 

+2

 

+3

 

+4

 

+5

 

+6

 

+7

 

+8

 

+9

Number of send data words

(Undefined) Unit No.

Input shift value

Input shift value

Input shift value

Input shift value

Input shift value

Input shift value

Input shift value

Input shift value

Channel 0

Channel 1

Channel 2

Channel 3

Channel 4

Channel 5

Channel 6

Channel 7

218