Omron CQM1H-SCB41 Restrictions in Using the CX-Protocol, Storage Memory, Restriction Procedure

Models: CQM1H-SCB41

1 421
Download 421 pages 6 Kb
Page 76
Image 76

Using Protocol Macros

Section 5-2

In this manual, the protocol structure is explained in simple terms, and examples are given of the use of the PMCR(––) instruction when controlling OMRON de- vices using standard system protocols. For details on the protocols, the method of modifying the standard system protocols, and the method of creating new se- quences, refer to the CX-Protocol Operation Manual (W344).

5-1-4 Storage Memory

The protocol macros are stored in flash memory in the Serial Communications Board and will be saved even if power to the CQM1H is turned OFF. The PC Set- up settings for the Serial Communications Board are stored in memory in the CPU Unit with a battery backup.

5-2 Restrictions in Using the CX-Protocol

There are some restrictions in using the CX-Protocol to manipulate protocols or perform other operations for the CQM1H-series Serial Communications Board. These restrictions are described below.

Pin 8 on the DIP switch on the front of the CQM1H-series CPU Unit must be turned ON to use the CX-Protocol. While pin 8 is ON, you will not be able to use any of the CPU Unit or Board ports for the CX-Programmer, SYSMAC-CPT, or SYSMAC Support Software.

The model of PC must be set to the C200HG and the model of CPU Unit must be set to the CPU43.

Refer to the following table for details and for other restrictions. Unless speci- fied, the functionality of the CX-Protocol will be the same as for the C200HX/ HG/HE.

Item

Restriction

Procedure

 

 

 

CQM1H DIP

Turn ON pin 8 on the DIP switch on the front of the

Turn ON pin 8 before using the

switch settings

CQM1H-series CPU Unit before attempting to use the

CX-Protocol.

 

CX-Protocol. You will not be able to use the

Turn OFF pin 8 after you are finished

 

CX-Protocol while pin 8 is OFF.

 

using the CX-Protocol.

 

While pin 8 is ON, you will not be able to use any of the

 

 

 

CPU Unit or Board ports for the CX-Programmer,

 

 

SYSMAC-CPT, or SYSMAC Support Software. Always

 

 

turn OFF pin 8 after you are finished using the

 

 

CX-Protocol.

 

 

 

 

PC model setting

Set the model of PC to the C200HG and the model of

1. Select New from the File Menu.

(to create new

CPU Unit to the CPU43-E.

2. Select C200HG from the Change PLC

protocols)

 

 

Dialog Box.

 

 

 

 

3. Select CPU43-Efrom the Settings

 

 

Dialog Box.

 

 

 

Transferring

You will not be able to upload the data for the standard

---

protocols to the

system protocols from the Board to the computer. If an

 

computer

attempt is made, the transfer will be canceled and the

 

 

following message will appear. (The standard system

 

 

protocol data in the Board will not be affected.)

 

 

Decompiler has detected an error. No protocol data

 

 

or invalid protocol list on upload. It is likely that the

 

 

previous download was interrupted or the PMSU

 

 

memory has been cleared/damaged. Try to

 

 

download a valid protocol and retry upload.

 

 

You will be able to download protocol data from the

 

 

computer to the Board (including data for the standard

 

 

system protocols) and will then be able to upload the

 

 

data. To modify the standard system protocols for your

 

 

applications, modify the data provided with the

 

 

CX-Protocol and then download the data to the Board.

 

65

Page 76
Image 76
Omron CQM1H-SCB41 operation manual Restrictions in Using the CX-Protocol, Storage Memory, Restriction Procedure