3Z4L Laser Micrometer Protocol

 

 

Appendix K

 

 

 

 

 

 

 

 

 

Sequence

Communications sequence

Function

Ladder interface

 

 

No.

name

 

 

 

 

 

 

 

Send word

 

Receive

 

 

 

 

 

 

 

 

 

 

 

allocation

 

word

 

 

 

 

 

 

 

allocation

 

 

 

 

 

 

 

 

 

 

418

All statistic memory clear

Clears statistic processing memories of all

No

 

No

 

 

 

(3000-series)

programs.

 

 

 

 

 

 

 

 

 

 

 

 

 

419

Statistic memory clear

Clears statistic processing memories of

No

 

No

 

 

 

(3000-series)

program under display.

 

 

 

 

 

 

 

 

 

 

 

 

 

420

Statistic result request

Requests statistic processing result.

No

 

Yes

 

 

 

(3000-series)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

421

Memory switch set 1

Sets memory switches.

Yes

 

No

 

 

 

(3000-series)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

422

Memory switch set 2

Sets memory switches.

Yes

 

No

 

 

 

(3000-series)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

423

Simple AVG times set

Taking the simple average as the averag-

Yes

 

No

 

 

 

(3000-series)

ing method, sets the averaging times per

 

 

 

 

 

 

 

measurement interval 4.

 

 

 

 

 

 

 

 

 

 

 

 

 

424

AVG move interval set

Taking the average move as the averag-

Yes

 

No

 

 

 

(3000-series)

ing method, sets the measurement inter-

 

 

 

 

 

 

 

val number.

 

 

 

 

 

 

 

 

 

 

 

 

 

425

AVG move (H) times set

Taking the average move and high-speed

Yes

 

No

 

 

 

(3000-series)

data output as the averaging method, sets

 

 

 

 

 

 

 

the averaging times per measurement in-

 

 

 

 

 

 

 

terval 4.

 

 

 

 

 

 

 

 

 

 

 

 

 

426

AVG move (L) times set

Taking the average move and low-speed

Yes

 

No

 

 

 

(3000-series)

data output as the averaging method, sets

 

 

 

 

 

 

 

the averaging times per measurement in-

 

 

 

 

 

 

 

terval 4.

 

 

 

 

 

 

 

 

 

 

 

 

 

427

Automatic detection set

Sets work automatic detection function.

Yes

 

No

 

 

 

(3000-series)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

428

Automatic detection release

Releases the settings of work automatic

No

 

No

 

 

 

(3000-series)

detection function.

 

 

 

 

 

 

 

 

 

 

 

 

 

429

Automatic detection list re-

Requests the settings of work automatic

No

 

Yes

 

 

 

quest (3000-series)

detection function.

 

 

 

 

 

 

 

 

 

 

 

 

 

430

3Z4L initialize (3000-series)

Clears the 3Z4L, sets the mm unit, sets

Yes

 

No

 

 

 

 

the memory unit, does not processes sta-

 

 

 

 

 

 

 

tistics, and clears all statistic memory.

 

 

 

 

 

 

 

 

 

 

 

 

 

431

Measurement condition set

Sets measurement conditions.

Yes

 

No

 

 

 

(4000-series)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

432

Measurement condition re-

Releases measurement conditions that

Yes

 

No

 

 

 

lease (4000-series)

have been set.

 

 

 

 

 

 

 

 

 

 

 

 

 

433

Measurement condition list re-

Requests the measurement conditions

No

 

Yes

 

 

 

quest (4000-series)

that have been set and other settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

434

Single run measurement start

When the sample measurement condition

No

 

Yes

 

 

 

(4000-series)

is from 1 to 999, performs a single run

 

 

 

 

 

 

 

measurement and requests the measure-

 

 

 

 

 

 

 

ment results.

 

 

 

 

 

 

 

 

 

 

 

 

 

435

Deflection measurement start

Starts a deflection measurement.

No

 

No

 

 

 

(4000-series)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

436

Continuous measurement

Starts a continuous measurement. The

No

 

Yes

 

 

 

start (scan) (4000-series)

scan notification method is used for re-

 

 

 

 

 

 

 

ceive data.

 

 

 

 

 

 

 

 

 

 

 

 

 

437

Continuous measurement

Starts a continuous measurement. The

No

 

Yes

 

 

 

start (interrupt) (4000-series)

interrupt notification method is used for

 

 

 

 

 

 

 

receive data.

 

 

 

 

 

 

 

 

 

 

 

 

 

438

Measurement termination

Terminates continuous measurement.

No

 

No *1

 

 

 

(4000-series)

 

 

 

 

 

318

Page 322
Image 322
Omron CQM1H-SCB41 operation manual Appendix K