E5ZE Temperature Controller Read Protocol

Appendix E

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of receive data words

0017

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Channel 0

0000 to 0500

 

 

 

 

Heater current

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+2

Channel 0

0000 to 0500

 

 

 

 

SSR leakage current

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

D

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

+15

Channel 7

0000 to 0500

 

 

 

 

Heater current

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+16

Channel 7

0000 to 0500

 

 

 

 

SSR leakage current

 

 

 

 

 

(4 digits BCD)

 

 

Note The read data will be 0000 for all channels for which HB and HS alarms are not enabled and for all channels for which control is stopped.

Read Dead Band/Overlap Band (Sequence No. 122)

Reads the dead bands/overlap bands and stores the results in the specified words.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Unit No.

 

 

 

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

+0

Number of send data words

0002

(fixed)

 

(4 digits BCD)

 

 

 

 

 

 

+1

Unit No. (2 digits Hex)

00 to

0F

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

 

 

Number of receive data words

 

 

 

 

storage words

 

 

 

 

 

 

 

 

 

 

+1

 

 

 

Dead band/overlap band

 

 

Channel 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

 

 

 

Dead band/overlap band

 

 

Channel 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

 

~

 

 

 

+8

 

 

 

Dead band/overlap band

 

 

Channel 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

 

Contents (data format)

Data

 

 

 

 

 

 

 

 

 

 

+0

 

 

Number of receive data words

 

0009

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+1

 

 

Channel 0

 

0000 to 0999

 

 

 

 

 

 

Dead band/overlap band

 

F indicates a number.

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

+2

 

 

Channel 1

 

0000 to 0999

 

 

 

 

 

 

Dead band/overlap band

 

F indicates a number.

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

+8

 

 

Channel 7

 

0000 to 0999

 

 

 

 

 

 

Dead band/overlap band

 

F indicates a number.

 

 

 

 

 

 

(4 digits BCD)

 

 

207

Page 213
Image 213