V600/V620 ID Controller Protocol

 

Appendix M

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of send data words

0006 to 0034

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Number of Heads

0001 to 0008

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+(4(N–1)+2)

Unit No. (2 digits BCD)

Arbitrary (However, there is a limit for the

 

 

 

 

 

maximum Unit No. depending on the model)

 

 

 

 

 

 

 

 

 

+(4(N–1)+3)

R/W Head CH No.

R/W Head CH 1 designation: 1

 

 

 

 

(1 digit BCD)

R/W Head CH 2 designation: 2

 

 

 

 

 

 

 

 

 

 

The CD1D must be set to 1.

 

 

 

 

 

 

 

 

 

+(4(N–1)+4)

Leading address No.

0000 to FFFF

 

 

 

 

(4 digits Hexadecimal)

 

 

 

 

 

 

 

 

 

 

+(4(N–1)+5)

Read bytes

01 to 0A (1 to 10 bytes)

 

 

 

 

(2 digits Hexadecimal)

 

 

 

 

 

 

 

 

N: Number of Heads

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

Number of receive data words

 

storage words

 

 

 

+1

Read data

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

+5

Read data

 

 

 

 

 

 

+6

Not used

 

 

 

 

 

 

~

~

 

 

 

 

 

+10

Not used

 

 

 

 

 

 

+11

Read data

 

 

 

 

 

 

~

~

 

+15

Read data

 

 

 

 

 

 

~

~

 

 

 

 

 

+71

Read data

 

 

 

 

 

 

~

~

 

 

 

 

 

+75

Read data

 

 

 

 

 

CH 1

CH 2

CH 8

Offset

Contents (data format)

Data

 

 

 

+0

Number of receive data

0002 to 0076

 

words (4 digits BCD)

 

 

 

 

+(10(N–1)+1) to

Read data (CH 1)

Number of read bytes stored in hexadecimal

+(10(N–1)+5)

(Hexadecimal)

data

 

 

 

N: Number of Heads

Note Data for Data Carriers designated for hexadecimal is sent beginning with the largest offset from the receive data words.

Auto-read (ASCII/1) (Sequence No. 508)

This sequence is used when the maximum number of Heads to be read from the Carrier is 1.

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 500 (Read (ASCII/1)).

Receive Data Word Allocation (3rd Operand of PMCR)

The receive data word allocation is similar to that of Sequence No. 500 (Read (ASCII/1)).

Note For auto-read (AR), a response is not returned if the number of Heads is not read by the Carrier, the Abort Bit must be turned OFF to terminate the sequence.

382

Page 385
Image 385