V600/V620 ID Controller Protocol

Appendix M

 

 

 

Note 1. Execute Sequence No. 536 before executing Sequence No. 537. 2. Retry processing is not performed for this sequence.

Polling Auto-write (Hexadecimal/8) (Sequence No. 538)

This sequence is used when the number of Heads to be written to the Carrier is 8.

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 525 (Write (Hexadecimal/8)).

Receive Data Word Allocation (3rd Operand of PMCR)

The receive data word allocation is similar to that of Sequence No. 525 (Write (Hexadecimal/8)).

Note 1. Execute Sequence No. 545 (Polling Auto-write Command Processing Cancel) to cancel the polling auto-write.

2. Retry processing is not performed for this sequence.

Polling Auto-write Subcommand (Hexadecimal/8) (Sequence No. 539)

This sequence is used when the number of Heads to be written to the Carrier is 8. Up to 10 digits of data can be written for each Read/Write Head.

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 525 (Write (Hexadecimal/8)). However, the lead- ing address No., number of write, and write data are not used and become undefined.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. Execute Sequence No. 538 before executing Sequence No. 539. 2. Retry processing is not performed for this sequence.

Data Check (Sequence No. 540)

This sequence writes and verifies the CRC code for check blocks designated by the user.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

+2

+3

+4

+5

Number of send data words

(Undefined)

 

Unit No.

 

 

 

(Undefined)

 

Head CH No.

 

 

 

Processing designation

(Undefined)

 

 

Leading address of check object

 

 

(Undefined)

Number of check block

 

bytes

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

+0

Number of send data words

0006 (fixed)

 

 

(4 digits BCD)

 

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 07 (CD1D)

 

 

00 to 15 (CA2A)

 

 

 

+2

R/W Head CH No.

R/W Head CH 1 designation: 1

 

(1 digit BCD)

R/W Head CH 2 designation: 2

 

 

 

 

The CD1D must be set to 1.

 

 

 

 

+3

Processing designation

Verification:

43 (C)

 

(2 digits Hexadecimal)

Calculation:

4B (K)

 

 

Management of number of write times: 4C (L)

 

 

 

 

+4

Leading address of check

0000 to FFFF

 

 

object

(If management of number of write times is

 

(4 digits Hexadecimal)

 

designated, H’ jjj0 to H’ jjj5 or H’ jjj8 to

 

 

 

 

H’ jjjD)

 

 

 

 

+5

Number of check block

If verification, calculation is designated:

 

bytes (2 digits

03 to FF (set 00 for 256 bytes)

 

Hexadecimal)

If management of number of write times is

 

 

designated: 00 to FF

 

 

 

 

398

Page 401
Image 401
Omron CQM1H-SCB41 Polling Auto-write Hexadecimal/8 Sequence No, Polling Auto-write Subcommand Hexadecimal/8 Sequence No