Index

Write Level 2 Parameters 1, 180

Write Level 2 Parameters 2, 181

Write Manual Reset Value, 173

Write MV at Stop Time and at PV Error, 175 Write MV Limits, 175

Write Proportional Band, Integral Time, and Derivative Time, 172

Write Set Point, 172

Write SP Ramp Time Unit and Set Value, 174

sequences, E5ZE Temperature Controller Cancel Autotuning, 218

Initialize Settings, 223

Read Alarm Mode, 197

Read Alarm Temperatures, 198 Read Control Period, 196 Read Cooling Coefficient, 208 Read Dead Band/Overlap Band, 207 Read Error Status, 200

Read HB Alarm and HS Alarm Valid Channels, 205

Read Heater Burnout and SSR Failure Detection Currents, 205

Read Heater Current and SSR Leakage Current, 206 Read Hysteresis, 199

Read Input Shift Value, 201 Read Manual Reset Value, 201 Read Operation Status, 199 Read Output Mode, 197

Read Output Value Change Rate Limit, 204 Read Output Value Limit, 203

Read Output Values, 193 Read Present Set Point, 203 Read Process Value, 192

Read Proportional Band, Integral Time, and Derivative Time, 195

Read Ramp Value, 202 Read Set Point, 191

Read Set Point, Process Value, and Output Value, 194 Read Setting Unit, 200

Save Settings, 223 Start Autotuning, 217 Start Control, 226

Start Manual Operation, 227 Stop Operation or Control, 226 Write Alarm Mode, 214

Write Alarm Temperature (Setting Unit 0.1), 216 Write Alarm Temperature (Setting Unit 1), 215 Write Control Period, 213

Write Cooling Coefficient, 225 Write Dead Band/Overlap Band, 225

Write HB and HS Alarm Valid Channels, 224

Write Heater Burnout and SSR Failure Detection Current, 224

Write Hysteresis, 217

Write Input Shift Value, 218 Write Manual Output Value, 220 Write Manual Reset Value, 219 Write Output Mode, 214

Write Output Value Change Rate Limit, 222 Write Output Value Limit, 221

Write Proportional Band, Integral Time, and Derivative Time, 212

Write Ramp Value, 220

Write Set Point (Setting Unit 0.1), 211

Write Set Point (Setting Unit 1), 210

Write Setting Unit, 218

sequences, ES100j Digital Controller Auto Mode, 276

Cancel A.T., 278 Change Bank No., 279 Change Pattern No., 279 Execute A.T., 277 External Setting Mode, 274 General-purpose Command, 281 Local Setting Mode, 274 Manual Mode, 277

Read Adjustment Parameters, 256 Read Control Monitor Data, 254 Read Controller Status, 280 Read Error Detection Data, 248 Read Event Data, 246

Read Heater Burnout Data, 250 Read Local SP, 267

Read MV Data, 253

Read PID Control Parameters 1, 260 Read PID Control Parameters 2, 262 Read Program Parameters, 270 Read PV Data, 251

Read SP Data, 252 Read Time Signal, 247 Remote Setting Mode, 273 Reset (Stop), 276

Run Command, 275

Write Adjustment Parameters, 259 Write Local SP, 269

Write PID Control Parameters 1, 264 Write PID Control Parameters 2, 266 Write Program Parameters, 272

sequences, Hayes Modem AT Command Data Send/Receive (General-purpose), 408 Dial, 406

Escape, 409

Escape to Hang Up, 403 Hang Up, 409 Initialize and Dial, 403

Initialize Modem (Specialized), 405 Password, 407

Set Modem (General-purpose), 405

415

Page 417
Image 417
Omron CQM1H-SCB41 operation manual 415