V600/V620 ID Controller Protocol

 

Appendix M

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of send data words

0007 to 0107

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Number of Heads

0001 to 0004

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+(14(N–1)+2)

Unit No. (2 digits BCD)

Arbitrary (However, there is a limit for the

 

 

 

 

 

maximum Unit No. depending on the model)

 

 

 

 

 

 

 

 

 

+(14(N–1)+3)

R/W Head CH No.

R/W Head CH 1 designation: 1

 

 

 

 

(1 digit BCD)

R/W Head CH 2 designation: 2

 

 

 

 

 

 

 

 

 

 

The CD1D must be set to 1.

 

 

 

 

 

 

 

 

 

+(14(N–1)+4)

Leading address No.

0000 to FFFF

 

 

 

 

(4 digits Hexadecimal)

 

 

 

 

 

 

 

 

 

 

+(14(N–1)+5)

Number of write digits

0002 to 0010

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+(14(N–1)+6)

Write data (Hexadecimal)

Input in hexadecimal code

 

 

 

to (14(N–1)+8)

 

Up to 10 digits (max.) can be set

 

 

 

 

 

 

 

N: Number of Heads

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. Write data designated for hexadecimal is sent beginning with the largest offset from the send data words.

2. Always set an even number of digits for the write data.

Auto-write (ASCII/1) (Sequence No. 526)

This sequence is used when the number of Heads to be written to the Carrier is 1.

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 518 (Write(ASCII/1)).

Receive Data Word Allocation (3rd Operand of PMCR)

The receive data word allocation is similar to that of Sequence No. 518 (Write(ASCII/1)).

Note For auto-write (AW), a response is not returned if the number of Heads is not written by the Carrier, the Abort Bit must be turned OFF to terminate the sequence.

Auto-write (Hexadecimal/1) (Sequence No. 527)

This sequence is used when the number of Heads to be written to the Carrier is 1.

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 522 (Write (Hexadecimal/1)).

Receive Data Word Allocation (3rd Operand of PMCR)

The receive data word allocation is similar to that of Sequence No. 522 (Write (Hexadecimal/1)).

Note For auto-write (AW), a response is not returned if the number of Heads is not written by the Carrier, the Abort Bit must be turned OFF to terminate the sequence.

Polling Auto-write (ASCII/2) (Sequence No. 528)

This sequence is used when the number of Heads to be written to the Carrier is 2.

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 519 (Write (ASCII/2)).

Receive Data Word Allocation (3rd Operand of PMCR)

The receive data word allocation is similar to that of Sequence No. 519 (Write (ASCII/2)).

Note 1. Execute Sequence No. 545 (Polling Auto-write Command Processing Cancel) to cancel the polling auto-write.

2. Retry processing is not performed for this sequence.

395

Page 398
Image 398
Omron CQM1H-SCB41 operation manual Auto-write ASCII/1 Sequence No, Auto-write Hexadecimal/1 Sequence No