Sequence

Communications

 

Function

Ladder interface

 

 

No.

sequence name

 

 

 

 

 

 

 

Send word

Receive word

 

 

 

 

 

 

 

 

 

 

 

 

allocation

allocation

 

 

471

Camera designation and

 

Designates the camera for measurement.

Yes

No

 

 

 

positioning (F350)

 

 

 

 

 

 

472

Scene switching and

 

Switches to a designated scene No.

Yes

No

 

 

 

positioning (F350)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

473

Inspection execution and

 

Carries out one inspection and outputs

No

No

 

 

 

character inspection

 

inspection results to the video monitor.

 

 

 

 

 

(F350)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

474

Character string inspec-

 

Changes the inspection character string

Yes

No

 

 

 

tion and character in-

 

of a designated inspection area No. to a

 

 

 

 

 

spection (F350)

 

designated character string.

 

 

 

 

 

 

 

 

 

 

 

 

480

Camera change (de-

 

Decreases the display camera No. by 1.

No

No

 

 

 

crease by 1) (F200/300)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

481

Camera change (in-

 

Increases the display camera No. by 1.

No

No

 

 

 

crease by 1) (F200/300)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

482

Binary level modification

 

Modifies the binary levels (upper limit and

Yes

No

 

 

 

(F200/300)

 

lower limit values) of a designated window

 

 

 

 

 

 

 

number No.

 

 

 

 

 

 

 

 

 

 

 

 

483

Reset (F200/300)

 

Resets the F200/F300.

No

No

 

 

 

 

 

 

 

 

 

 

490

Scene switch (decrease

 

Decreases the scene No. by 1.

No

No

 

 

 

by 1)

 

 

 

 

 

 

491

Scene switch (increase

 

Increases the scene No. by 1.

No

No

 

 

 

by 1)

 

 

 

 

 

 

492

Scene switch (arbitrary)

 

Switches to a designated scene No.

Yes

No

 

 

 

 

 

 

 

 

 

 

493

Measurement, inspec-

 

Terminates the measurement and returns

No

No

 

 

 

tion termination

 

to the home menu.

 

 

 

 

 

 

 

 

 

 

 

 

494

General-purpose com-

 

Sets and executes commands that are

Yes

No

 

 

 

mand (send)

 

otherwise not supported.

 

 

 

 

 

 

 

 

 

 

 

 

495

General-purpose com-

 

Sets and executes commands that are

Yes

Yes

 

 

 

mand (send/receive)

 

otherwise not supported.

 

 

 

Note Ladder Interface Settings

 

YES:

User settings are required for the 2nd and 3rd operands of PMCR.

NO:

Send word allocation:

Set a dummy word address for the 3rd operand (D).

 

Receive word allocation:

Set the constant 0000 for the 2rd operand (S).