E5jK Digital Controller Write Protocol

Appendix D

 

 

 

Write Level 1 Parameters 1 (Sequence No. 066)

Writes parameters in level 1 (alarm value 1, alarm value 2, alarm value 3, proportional band, integral time, and derivative time) to multiple units.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

 

Number of send data words

 

 

send data

 

 

 

 

 

 

+1

 

Number of units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

 

(Undefined)

Unit No.

 

 

 

 

 

 

 

 

 

 

+3

 

Alarm value 1

 

 

 

 

 

 

 

 

 

+4

 

Alarm value 2

 

 

 

 

 

 

 

 

 

+5

 

Alarm value 3

 

 

+6

 

Proportional band

 

 

+7

 

Integral time

 

 

 

 

 

 

+8

 

Derivative time

 

 

 

~

 

~

 

+51

 

 

 

 

 

 

 

(Undefined)

Unit No.

 

 

 

+52

 

 

 

 

 

 

 

Alarm value 1

 

 

+53

 

 

 

 

 

 

 

Alarm value 2

 

 

+54

 

 

 

 

 

 

 

Alarm value 3

 

 

+55

 

 

 

 

 

 

 

Proportional band

 

 

 

 

 

 

 

 

 

+56

 

Integral time

 

 

 

 

 

 

 

 

 

+57

 

Derivative time

 

 

 

 

 

 

 

 

1st unit

8th unit (max.)

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

Number of units  7 + 2

 

(4 digits BCD)

 

 

 

 

+1

Number of units (4 digits BCD)

0001 to 0008

 

 

 

+2

1st unit

00 to 31

 

Unit No. (2 digits BCD)

 

 

 

 

+3

1st unit

A999 to 9999

 

Alarm value 1 (4 digits BCD)

F indicates a negative value and A

 

 

indicates –1.

 

 

 

+4

1st unit

A999 to 9999

 

Alarm value 2 (4 digits BCD)

F indicates a negative value and A

 

 

indicates –1.

 

 

 

+5

1st unit

A999 to 9999

 

Alarm value 3 (4 digits BCD)

F indicates a negative value and A

 

 

indicates –1.

 

 

 

+6

1st unit

0001 to 9999

 

Proportional band (4 digits BCD)

 

 

 

 

+7

1st unit

0000 to 3999

 

Integral time (4 digits BCD)

 

 

 

 

+8

1st unit

0000 to 3999

 

Derivative time (4 digits BCD)

 

 

 

 

 

D

 

 

D

 

 

D

 

 

 

 

+57

8th unit

0000 to 3999

(max.)

Derivative time (4 digits BCD)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

178

Page 185
Image 185
Omron CQM1H-SCB41 operation manual Write Level 1 Parameters 1 Sequence No