Visual Inspection System Protocol

 

Appendix L

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of send data words

0002

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Scene No. (2 digits BCD)

00 to 15

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. If a scene No. is abnormal, CIO 28909 (if port A is used) or CIO 28913 (if port B is used) will turn ON.

2.Retry processing is not performed for this sequence.

3.Turn the Abort Bit ON and then OFF to end this sequence.

Inspection Execution and Character Inspection (F350) (Sequence No. 473)

This sequence carries out one inspection and outputs the inspection results to a video monitor.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Character String Inspection and Character Inspection (F350) (Sequence No. 474)

This sequence changes the inspection character string of a designated inspection area No. to a designated char- acter string.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

+2

+3

~

Number of send data words

Inspection area No.

 

(Undefined)

Number of designated character strings

 

 

 

 

 

 

 

 

 

Designated character string

 

 

 

 

Designated character string

~

 

 

 

 

 

 

 

 

 

 

 

 

Offset

 

Contents (data format)

Data

 

 

 

 

+0

 

Number of send data words

0004 to 0015

 

 

(4 digits BCD)

 

 

 

 

 

 

 

+1

 

Number of designated character

0 to 24

 

 

strings (4 digits BCD)

 

 

 

 

 

 

 

 

+2

 

Inspection area No.

 

00 to 07

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

+3 to

 

Number of designated character

 

 

 

 

strings (ASCII)

 

 

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Camera Change (Decrease by 1) (F200/300) (Sequence No. 480)

This sequence decreases the display camera No. by 1.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

363

Page 366
Image 366
Omron CQM1H-SCB41 operation manual Camera Change Decrease by 1 F200/300 Sequence No