V600/V620 ID Controller Protocol

Appendix M

 

 

 

Read (ASCII/1) (Sequence No. 500)

This sequence is used when the number of Heads to be read from the Carrier is 1.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

+2

+3

+4

Number of send data words

(Undefined)

 

Unit No.

 

 

 

(Undefined)

 

Head CH No.

 

 

Leading address No.

 

 

(Undefined)

Read bytes

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0005 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 07 (CD1D)

 

 

00 to 15 (CAjA)

 

 

 

+2

R/W Head channel

R/W Head CH 1 designation: 1

 

(CH) No. (1 digit BCD)

R/W Head CH 2 designation: 2

 

 

 

 

The CD1D must be set to 1.

 

 

 

+3

Leading address No.

0000 to FFFF

 

(4 digits Hexadecimal)

 

 

 

 

+4

Read bytes

01 to F4 (1 to 244 bytes)

 

(2 digits Hexadecimal)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

 

Number of receive data words

 

 

storage words

 

 

 

 

 

 

+1

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

 

 

 

 

+122

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

 

+0

Number of receive data

0002 to 0123

 

 

 

 

words (4 digits BCD)

 

 

 

 

 

 

 

 

 

 

+1 to +122

Read data (ASCII)

Number of read bytes stored in ASCII

Note Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the receive data words.