3Z4L Laser Micrometer Protocol

Appendix K

 

 

 

Automatic Detection Set (3000-series, High-speed Type) (Sequence No. 427)

This sequence sets the work automatic detection function.

Send Data Word Allocation (2nd Operand of PMCR)

Receive data

+0

Number of send data words

storage words

 

 

 

 

 

 

+1

(Undefined)

 

 

The number of measuring times

 

 

 

 

 

 

 

 

 

 

 

+2

 

 

 

Invalid time

 

 

 

 

 

 

 

 

+3

 

 

 

Decimal portion

 

 

 

 

 

 

+4

(Undefined)

 

 

Integer portion

 

 

 

 

 

 

 

+5

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

+6

 

 

 

Decimal portion

 

 

 

 

 

 

+7

(Undefined)

 

 

Integer portion

 

 

 

 

 

 

 

+8

Sign

 

(Undefined)

 

 

 

 

 

 

 

Detection lower limit

Detection upper limit

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

 

 

+0

Number of send data words

0009 (fixed)

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+1

Number of measurements

001 to 999

 

 

 

 

(3 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+2

Invalid time (4 digits BCD)

0001 to 9999

 

 

 

 

 

 

 

 

 

+3

Detection lower limit

0000 to 9999

 

Example –123.4567

 

(decimal portion)

 

 

 

 

 

 

 

 

+3

4 5 6 7

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

+4

0 1 2 3

 

+4

Detection lower limit

000 to 999

 

 

 

(integer portion)

 

 

 

 

 

 

 

 

+5

2 D 0 0

 

 

(3 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+5

Detection lower limit (Sign)

If +: 20 (‘ ’)

 

 

 

 

 

(ASCII 1 character)

If – : 2D (‘–’)

 

 

 

 

 

 

 

 

 

 

 

+6 to

Detection upper limit

Same as detection lower limit

 

 

 

+8

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.

Automatic Detection Release (3000-series, High-speed Type) (Sequence No. 428)

This sequence releases the setting of work automatic detection function.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.

Automatic Detection List Request (3000-series, High-speed Type) (Sequence No. 429)

This sequence requests the settings of work automatic detection function.

Send Data Word Allocation (2nd Operand of PMCR)

None.

338

Page 342
Image 342