3Z4L Laser Micrometer Protocol

Appendix K

 

 

 

Statistic Processing Non-execution (3000-series) (Sequence No. 417)

This sequence turns the statistic processing LED off and does not carry out the statistic processing.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

All Statistic Memory Clear (3000-series) (Sequence No. 418)

This sequence clears statistic processing memories of all programs.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Statistic Processing Memory Clear (3000-series) (Sequence No. 419)

This sequence clears statistic processing memories of the program under display.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Statistic Result Request (3000-series) (Sequence No. 420)

This sequence requests the statistic processing results.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

Number of receive data words

storage words

 

 

 

 

 

 

+1

(Undefined)

 

 

 

 

 

 

+2

 

 

 

 

 

 

 

 

 

 

 

 

+3

(Undefined)

 

 

 

 

 

 

 

 

 

 

 

 

 

+4

 

Decimal portion

 

 

 

 

 

 

 

 

 

 

+5

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+6

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

+7

 

Decimal portion

 

 

 

 

 

 

 

 

 

 

+8

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+9

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

+10

 

Decimal portion

 

 

 

 

 

 

 

 

+11

(Undefined)

 

Integer portion

 

 

 

 

 

 

+12

Sign

 

(Undefined)

 

 

+13

 

Decimal portion

 

 

 

 

 

 

 

 

+14

(Undefined)

 

Integer portion

 

+15

Sign

 

(Undefined)

 

 

+16

 

Decimal portion

 

 

 

+17

(Undefined)

 

Integer portion

 

+18

Sign

 

(Undefined)

 

Program number (P)

Number of statistic data (N)

Average value (AVG)

Maximum value (MAX)

Minimum value (MIN)

Range (R)

Standard deviation (SD)

333

Page 337
Image 337
Omron CQM1H-SCB41 operation manual Statistic Processing Non-execution 3000-series Sequence No