ES100j Digital Controller Protocol

 

Appendix H

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

+0

Number of send data words

0044 (fixed)

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 31

 

 

 

 

 

 

 

 

 

+2 to 3

Fixed SP (8 digits BCD)

00000000 to 09999000

 

 

 

 

 

 

 

 

 

+4 to 5

Control output 1 pulse cycle

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+6 to 7

Control output 2 pulse cycle

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+8 to 9

Fuzzy strength (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+10 to 11

Cooling coefficient (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+12 to 13

Heater burnout alarm setting

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+14 to 15

Position-proportional dead band

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+16 to 17

Switching output hysteresis

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+18 to 19

ON/OFF count alarm setting

 

 

 

 

 

(8 digits BCD) value

 

 

 

 

 

 

 

 

 

 

+20 to 21

ON/OFF control hysteresis

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+22 to 23

Manual reset (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+24 to 25

SP setting lower limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+26 to 27

SP setting upper limit

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+28 to 29

SP rise rate limit (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+30 to 31

SP fall rate limit (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+32 to 33

MV rate-of-change limit (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+34 to 35

Secondary loop fixed SP

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+36 to 37

Secondary loop P (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+38 to 39

Secondary loop I (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+40 to 41

Secondary loop D (8 digits BCD)

 

 

 

 

 

 

 

 

 

 

+42 to 43

Secondary loop manual reset

 

 

 

 

 

(8 digits BCD)

 

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Read PID Control Parameters 1 (Sequence No. 260)

Reads PID parameters No. 1 to 4 from PID control parameters in the parameter area and stores the results in the specified words.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Unit No.

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0002 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 31

260

Page 265
Image 265
Omron CQM1H-SCB41 Read PID Control Parameters 1 Sequence No, Receive Data Word Allocation 3rd Operand of Pmcr