Omron CQM1H-SCB41 operation manual Polling Auto-read Command Processing Cancel Sequence No

Models: CQM1H-SCB41

1 421
Download 421 pages 6 Kb
Page 404
Image 404

V600/V620 ID Controller Protocol

 

Appendix M

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of receive data

0002 (fixed)

 

 

 

 

words (4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Completion code

00: Normal termination

 

 

 

 

(2 digits Hexadecimal)

14: Auto or communications command processing

 

 

 

 

 

 

 

 

 

 

not executed

 

 

 

 

 

75: Cancelled before the end of expansion

 

 

 

 

 

command receive or before sync input went

 

 

 

 

 

active or before detection of the existence of

 

 

 

 

 

Data Carrier

 

 

 

 

 

76: Cancelled during read/write processing for Data

 

 

 

 

 

Carrier

 

 

 

 

 

 

 

Polling Auto-read Command Processing Cancel (Sequence No. 544)

This sequence cancels polling auto-read processing.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

+2

+3

Number of send data words

(Undefined)

Unit No.

 

 

(Not used)

 

 

(Undefined)

Head channel No.

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0004 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits BCD)

Arbitrary (However, there is a limit for the

 

 

maximum Unit No. depending on the

 

 

model)

 

 

 

+2

Not used

 

 

 

 

+3

R/W Head CH No. (1 digit BCD)

R/W Head CH 1 designation: 1

 

 

R/W Head CH 2 designation: 2

 

 

The CD1D must be set to 1.

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

Number of receive data words

storage words

+1

 

 

(Undefined)

Completion code

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of receive data

0002 (fixed)

 

words (4 digits BCD)

 

 

 

 

+1

Completion code

75: Cancelled before communications processing

 

(2 digits Hexadecimal)

with Data Carrier

 

 

76: Cancelled after communications processing with

 

 

Data Carrier

 

 

 

Polling Auto-write Command Processing Cancel (Sequence No. 545)

This sequence cancels polling auto-write processing

Send Data Word Allocation (2nd Operand of PMCR)

The send data word allocation is similar to that of Sequence No. 544 (Polling Auto-read Command Processing Cancel)

Receive Data Word Allocation (3rd Operand of PMCR)

The receive data word allocation is similar to that of Sequence No. 544 (Polling Auto-read Command Processing Cancel)

401