3Z4L Laser Micrometer Protocol

Appendix K

 

 

 

Program Number Set (3000-series) (Sequence No. 406)

This sequence switches the program number to a specified number.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

Number of send data words

(Undefined)

Program number (1 digit BCD)

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0002 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Program number (1 digit BCD)

0 to 9

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note Retry processing is not performed for this sequence.

Measurement Condition Set (3000-series) (Sequence No. 407)

This sequence sets measurement conditions. Conditions to be set can be selected by setting Yes/No flags.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

Number of send data words

 

data

 

 

 

 

 

 

 

(Unused)

 

+1

 

 

+2

 

 

 

 

 

 

 

 

 

 

 

 

+3

 

 

 

 

 

 

 

 

 

 

 

 

+4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+5

(Undefined)

 

 

 

 

 

 

 

 

 

 

 

+6

 

Decimal portion

 

 

 

 

 

 

 

 

 

 

+7

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+8

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

 

+9

 

Decimal portion

 

+10

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+11

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

 

+12

 

Decimal portion

 

+13

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+14

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

 

+15

 

Decimal portion

 

+16

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+17

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

 

+18

 

Decimal portion

 

 

 

 

 

 

 

 

 

 

+19

(Undefined)

 

Integer portion

 

 

 

 

 

 

 

 

+20

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

 

+21

 

Decimal portion

 

+22

(Undefined)

 

Integer portion

 

+23

 

 

 

 

 

 

Sign

 

(Undefined)

 

 

 

+24

 

 

 

 

 

 

 

Decimal portion

 

 

 

+25

 

 

 

 

 

 

(Undefined)

 

Integer portion

 

+26

 

 

 

 

 

 

Sign

 

(Undefined)

 

 

 

+27

 

 

 

 

 

 

 

Decimal portion

 

+28

(Undefined)

 

Integer portion

 

+29

 

 

 

 

 

 

Sign

 

(Undefined)

 

 

 

 

 

 

 

 

 

 

Segment number (SG)

Measurement interval number (M)

Lower limit value (LL)

Upper limit value (LH)

Multistep selection limit value (L1)

Multistep selection limit value (L2)

Multistep selection limit value (L3)

Multistep selection limit value (L4)

Multistep selection limit value (L5)

Multistep selection limit value (L6)

325

Page 329
Image 329
Omron CQM1H-SCB41 Program Number Set 3000-series Sequence No, Measurement Condition Set 3000-series Sequence No