Omron CQM1H-SCB41 operation manual 327

Models: CQM1H-SCB41

1 421
Download 421 pages 6 Kb
Page 331
Image 331

3Z4L Laser Micrometer Protocol

 

 

 

Appendix K

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

 

Data

 

 

 

 

 

 

 

 

 

+30 to

Reference value

Same as lower limit values

 

 

+32

 

 

 

 

 

 

 

 

 

 

 

 

 

+33

Analog output scale number

1 to 3

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+34 to

Offset classification (ASCII

4F4620 (“OF”), 4F4D20 (“OM”)

 

 

+35

3 characters)

 

 

 

 

 

 

 

 

 

 

 

 

+36 to

Offset value

Same as lower limit values

 

 

+38

 

 

 

 

 

 

 

 

 

 

 

 

 

+39

Data output conditions

0 to 6

 

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

+40

Scheduled output timer

000 to 999

 

 

 

 

 

(3 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

+41

Sample measurement pulse

000 to 999

 

 

 

 

 

(3 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+42 to

Sample measurement

415647 (“AVG”), 4D4158 (“MAX”)

 

 

+43

classification

4D494E (“MIN”), 524E47 (“RNG”)

 

 

 

 

(ASCII 3 characters)

 

 

 

 

 

 

 

 

 

 

 

 

 

+44 to

Unused

Undefined

 

 

 

+45

 

 

 

 

 

 

 

 

 

 

 

 

 

+46

Yes/No for segment setting

Set:

1

(SG)

 

 

 

 

(1 digit BCD)

Don’t set: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+47

Yes/No for measurement

Set:

1

(M)

 

 

 

 

interval number setting

Don’t set: 0

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+48

Yes/No for upper/lower limit

Set:

1

(LL,LH)

 

 

 

 

value setting

Don’t set: 0

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+49

Yes/No for multistep

Set:

1

(L1,L2,L3,L4,L5,L6)

 

 

 

 

selection limit value

Don’t set: 0

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+50

Yes/No for reference setting

Set:

1

(REF, SCL)

 

 

 

 

(1 digit BCD)

Don’t set: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+51

Yes/No for offset value

Set:

1

(OF or OM)

 

 

 

 

setting (1 digit BCD)

Don’t set: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+52

Yes/No for data output

Set:

1

(PR, PRT)

 

 

 

 

condition setting

Don’t set: 0

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+53

Yes/No for sample

Set:

1

(SMP, MAX or MIN or RNG or AVG)

 

 

 

 

measurement pulse setting

Don’t set: 0

 

 

 

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. This sequence cannot be used to set the error lower limit (EL), error upper limit (EH), error exclusion counter (CNT) of the error data exclusion function (centerless grinder function).

2.The following settings must be made together with this sequence; they cannot be set separately. Lower limit, upper limit

Multistep selection limit

Reference value, analog output scale number Data output conditions, scheduled print timer

3.The limit value, reference value, and offset value can be set to 3 digits for the integer portion and to 4 dig- its for the decimal portion.

327