E5jK Digital Controller Write Protocol

Appendix D

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Write Level 0 Parameters (Sequence No. 065)

Writes parameters (set points) in level 0 to multiple units.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

 

Number of send data words

 

send data

 

 

 

 

 

 

+1

 

Number of units

 

 

 

 

 

 

 

 

 

 

 

 

+2

 

(Undefined)

 

Unit No.

 

 

 

 

 

 

 

 

 

+3

 

Set point

 

 

 

+4

 

(Undefined)

 

Unit No.

 

 

 

 

 

 

+5

 

Set point

 

 

 

 

 

 

 

 

 

~

 

 

~

1st unit

2nd unit

+16

+17

(Undefined)

Unit No.

Set point

8th unit (max.)

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

Number of units  2 + 2

 

(4 digits BCD)

 

 

 

 

+1

Number of units (4 digits BCD)

0001 to 0008

 

 

 

+2

1st unit

00 to 31

 

Unit No. (2 digits BCD)

 

 

 

 

+3

1st unit

Set point lower limit to upper limit

 

Set point (4 digits BCD)

 

 

 

 

 

D

 

 

D

 

 

D

 

 

 

 

+17

8th unit

Set point lower limit to upper limit

(max.)

Set point (4 digits BCD)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

177

Page 184
Image 184
Omron CQM1H-SCB41 operation manual Write Level 0 Parameters Sequence No