Visual Inspection System Protocol

Appendix L

 

 

 

Scene Switching (Arbitrary) (Sequence No. 492)

This sequence switches to a designated scene No.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Scene No.

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0002

 

(4 digits BCD)

 

 

 

 

+1

Scene No. (2 digits BCD)

00 to 15

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Measurement, Inspection Termination (Sequence No. 493)

This sequence terminates the measurement and returns to the home menu.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

General-purpose Command (Send) (Sequence No. 494)

This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is auto- matically attached to the send data.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

 

 

send data

 

 

 

 

 

 

 

+1

 

Command length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

(Undefined)

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

 

 

~

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

+0

Number of send data words

003 to 0129

 

 

 

(4 digits BCD)

 

 

 

 

 

+1

Command length (4 digits BCD)

0001 to 0253

 

 

+2 to

Command (ASCII)

Specify ASCII data.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Note 1. The processing depends on the command.

2. For a command with a response, use sequence #495.

General-purpose Command (Send/Receive) (Sequence No. 495)

This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is auto- matically attached to the send data.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

 

Number of send data words

 

send data

 

 

 

 

 

+1

 

Command length

 

 

 

 

 

 

 

 

 

 

 

+2

 

(Undefined)

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

 

~

 

 

 

 

 

 

365

Page 368
Image 368