V500/V520 Bar Code Reader Protocol

Appendix J

 

 

 

BCR Function Write (V500) (Sequence No. 354)

This sequence sets the operation mode and read functions in the Bar Code Reader.

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

send data

+1

+2

+3

+4

+5

+6

Number of send data words

Operation mode

In-zone control

 

 

 

Types of bar code

(Undefined)

 

 

 

(Undefined)

Number of digits

 

 

 

Modulus check

(Undefined)

 

 

 

(Undefined)

Number of

Multistep

matches

labels

 

Buzzer

Horizontal control

 

 

 

Offset

Contents (data format)

 

 

Data

 

 

 

+0

Number of send data words

0007 (fixed)

 

(4 digits BCD)

 

 

 

 

 

 

 

 

+1

Operation mode

41

(‘A’) :

ONLINE

 

(ASCII 1 character)

*42 (‘B’) :

ONLINE CONTROL

 

 

 

 

 

In-zone control

*41 (‘A’) :

ON

 

(ASCII 1 character)

42

(‘B’) :

OFF

 

 

 

 

 

+2

Bar code type

41

(‘A’) :

JAN

 

(ASCII 1 character)

42

(‘B’) :

NW7 NORMAL

 

 

43

(‘C’) :

NW7 SMALL

 

 

44

(‘D’) :

NW7 HEX

 

 

45

(‘E’) :

CODE39 NORMAL

 

 

46

(‘F’) :

CODE39 ST/SP OUTPUT

 

 

47

(‘G’) :

2 of 5 (ITF)

 

 

48

(‘H’) :

CODE128

 

 

49

(‘I’) :

CODE93

 

 

4A (‘J’) :

2 of 5 (3BAR)

 

 

4B (‘K’) :

2 of 5 (5BAR)

 

 

 

 

+3

Number of digits

00 to 32

 

 

(2 digits BCD)

00: Any number of digits allowed.

 

 

 

 

 

+4

Modulus check

41

(‘A’) :

No-check

 

(ASCII 1 character)

42

(‘B’) :

Modulus 10 (all bar codes)

 

 

43

(‘C’) :

Modulus 11 (except JAN)

 

 

44

(‘D’) :

Modulus 16 (NW7 only)

 

 

45

(‘E’) :

Modulus 43 (CODE39 only)

 

 

46

(‘F’) :

Modulus 47 (CODE93 only)

 

 

47

(‘G’) : Modulus 103 (CODE128 only)

 

 

 

 

+5

Number of matches

1 to 5

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

Multistep labels

1 to 4

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

+6

Buzzer

41

(‘A’) :

ON for normal read

 

(ASCII 1 character)

42

(‘B’) :

ON for no-read

 

 

43

(‘C’) :

OFF

 

 

 

 

 

 

Horizontal control mode

41

(‘A’) :

Normal (continuous rotating)

 

(ASCII 1 character)

42

(‘B’) :

In-zone startup

 

 

 

 

 

Note Selecting the values marked with asterisks is required for this protocol.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

310

Page 314
Image 314
Omron CQM1H-SCB41 operation manual BCR Function Write V500 Sequence No, CODE93