Visual Inspection System Protocol

 

Appendix L

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

+0

Number of send data words

0003 to 0129

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

+1

Command length (4 digits BCD)

0001 to 0253

 

 

 

 

 

 

 

 

 

+2 to

Command (ASCII)

Specify ASCII data.

 

Receive Data Word Allocation (3rd Operand of PMCR)

The reception data is stored in the reception data words without the delimiter (CR+LF),

Receive data

+0

Number of receive data words

 

 

storage words

 

 

 

 

 

 

 

+1

 

Command length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

(Undefined)

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

 

 

~

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

+0

Number of receive data words

 

 

 

 

(4 digits BCD)

 

 

 

 

 

+1

Command length (4 digits BCD)

 

 

 

+2 to

Command (ASCII)

ASCII data is returned.

Note 1. The processing depends on the command.

2. For a command with a response, use sequence #495.