K3Tj Intelligent Signal Processor Protocol

 

 

 

Appendix I

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

 

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+0

Number of send data words

0004 to 0098

 

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1

Number of units

01 to 32

 

 

 

 

 

 

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

Bank No.

01 to 04

 

 

 

 

 

 

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+3 to

Set value

00000 to 99999

 

 

 

 

 

+4

(5 digits BCD)

Negative sign: F (most significant digit)

 

 

 

 

 

Example 12345

Example –1234

 

 

 

 

 

+2

 

 

 

 

 

 

 

 

 

2345

+2

1234

 

 

 

 

 

 

+3

 

+3

 

 

 

 

 

 

 

0001

000F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+96 to

Set value

Same as above

 

 

 

 

 

+97

(5 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Write Set Value H with Bank (Continuous Units) (Sequence No. 309)

This sequence writes set value H of a bank not in use for continuous units. The word allocation is identical to that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).

Write Set Value L with Bank (Continuous Units) (Sequence No. 310)

This sequence writes set value L of a bank not in use for continuous units. The word allocation is identical to that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).

Write Set Value LL with Bank (Continuous Units) (Sequence No. 311)

This sequence writes set value LL of a bank not in use for continuous units. The word allocation is identical to that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).

Write Set Value O5 with Bank (Continuous Units) (Sequence No. 312)

This sequence writes set value O5 of a bank not in use for continuous units. The word allocation is identical to that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).

Write Set Value O4 with Bank (Continuous Units) (Sequence No. 313)

This sequence writes set value O4 of a bank not in use for continuous units. The word allocation is identical to that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).

Write Set Value O3 with Bank (Continuous Units) (Sequence No. 314)

This sequence writes set value O3 of a bank not in use for continuous units. The word allocation is identical to that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).

292

Page 297
Image 297
Omron CQM1H-SCB41 operation manual Write Set Value H with Bank Continuous Units Sequence No