3Z4L Laser Micrometer Protocol

Appendix K

 

 

 

General-purpose Command 1 (4000-series) (Sequence No. 444)

This general-purpose command is used to send data with a specified data length, and receive back only OK. The terminator (CR) is automatically attached to the send data.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

send data

+1

 

 

+2

 

+3

Number of send data words

Send data byte length

Send data

Send data

 

 

 

D

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

+128

 

Send data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+129

 

Send data

 

CR

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

 

 

+0

Number of send data words

 

0003 to 0129

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

+1

Send data byte length (4 digits BCD)

0001 to 0255

 

 

 

 

 

 

The number of bytes of send data

 

 

 

 

 

 

excluding the terminator (CR)

 

 

 

 

 

 

+2 to

Send data (ASCII)

 

Send data up to 255 bytes maximum

 

+129

 

 

 

Specify in ASCII.

 

 

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.