E5ZE Temperature Controller Read Protocol

Appendix E

 

 

 

Read Cooling Coefficient (Sequence No. 123)

Reads the cooling coefficients and stores the results in the specified words.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Unit No.

 

 

 

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

+0

Number of send data words

0002

(fixed)

 

(4 digits BCD)

 

 

 

 

 

 

+1

Unit No. (2 digits Hex)

00 to

0F

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

 

Number of receive data words

 

 

 

 

 

storage words

 

 

 

 

 

 

 

 

 

+1

 

 

Cooling coefficient

 

 

Channel 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

 

 

Cooling coefficient

 

 

Channel 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

+8

 

 

Cooling coefficient

 

 

Channel 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

Data

 

 

 

 

 

 

 

 

 

 

 

+0

Number of receive data words

 

0009

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1

Channel 0

 

0000 to 0100

 

 

 

 

 

Cooling coefficient (4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

Channel 1

 

0000 to 0100

 

 

 

 

 

Cooling coefficient (4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+8

Channel 7

 

0000 to 0100

 

 

 

 

 

Cooling coefficient (4 digits BCD)

 

 

208

Page 214
Image 214