Output No.
Decimal portion

Visual Inspection System Protocol

Appendix L

 

 

 

3.The ranges of measurement values are as follows:

For calibration OFF setting : –2147483.648 to 2147483.647

For calibration ON setting : –9999999.999 to 9999999.999

4.If a measurement value exceeds the range of measurement values when calibration is turned off, unde- fined data is stored in the specified words.

Reference Object Registration (Group) (F200) (Sequence No. 453)

This sequence performs reference position registration and criterion registration at the same time.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Reference Object Registration (Reference Position) (F200) (Sequence No. 454)

This sequence registers the reference position for measuring the amount of position displacement when a position displacement compensation is used.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Reference Object Registration (Criterion) (F200) (Sequence No. 455)

This sequence registers a reference value to discriminate the output format.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Evaluation Condition Change (F200) (Sequence No. 456)

This sequence changes the upper and lower limit values of evaluation condition of the designated output No.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

Number of send data words

(Undefined)

+2

+3

+4

(Undefined)

(Undefined)

Integer portion

Upper limit value

+5

+6

+7

+8

+9

Sign

 

(Undefined)

 

 

 

 

(Undefined)

 

Decimal portion

 

 

 

 

 

Integer portion

(Undefined)

 

 

 

 

 

 

 

 

Sign

 

(Undefined)

 

 

 

 

Lower limit value

354

Page 357
Image 357
Omron CQM1H-SCB41 Reference Object Registration Group F200 Sequence No, Evaluation Condition Change F200 Sequence No