E5jK Digital Controller Read Protocol

Appendix C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

+0

Number of send data words

0002 (fixed)

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 31

 

Receive Data Word Allocation (3rd Operand of PMCR)

 

 

 

 

 

 

 

 

 

 

 

Receive data

+0

 

Number of receive data words

 

 

 

 

storage words

 

 

 

 

 

 

 

 

+1

 

 

SP ramp time unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+2

 

 

SP ramp set value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

 

 

 

 

 

 

 

 

+0

Number of receive data words

0003

 

 

 

 

 

 

(4 digits BCD)

 

 

 

 

 

 

 

 

 

 

 

 

+1

SP ramp time unit (4 digits BCD)

0000: s, 0001: hr

 

 

 

 

 

 

 

 

 

 

 

+2

SP ramp set value (4 digits BCD)

0000 to 9999

 

Read LBA Detection Time (Sequence No. 012)

Reads the LBA (loop break alarm) detection time and stores the results in the specified words.

Send Data Word Allocation (2nd Operand of PMCR)

First word of

+0

Number of send data words

send data

 

 

 

+1

(Undefined)

Unit No.

 

 

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0002 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 31

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

storage words

+1

 

Number of receive data words

LBA detection time

Offset

Contents (data format)

Data

 

 

 

+0

Number of receive data words

0002

 

(4 digits BCD)

 

 

 

 

+1

LBA detection time (4 digits BCD)

0000 to 9999

160

Page 167
Image 167