Board Replacement

 

 

 

 

Section 9-2

 

 

 

 

 

 

 

 

 

Error

Indicator

Error details

Cause

 

Remedy

 

code

 

 

 

 

 

 

 

2 Hex

No display

Sequence

The

Correct the communications sequence

 

 

 

number error

communications

number.

 

 

 

 

sequence number

Use CX-Protocol to register the

 

 

 

 

specified in bits 00

 

 

 

 

specified communications sequence

 

 

 

 

to 11 of the

 

 

 

 

number.

 

 

 

 

PMCR(––)

 

 

 

 

 

 

 

 

 

 

 

instruction’s C

 

 

 

 

 

 

 

operand is not

 

 

 

 

 

 

 

registered.

 

 

 

 

 

 

 

 

 

 

3 Hex

ERR/ALM

Receive data

The data range of

For operand specification:

 

 

: Flashing

write range

the specified area

Check the PMCR(––) instruction S and

 

 

 

overflow error

is exceeded when

D operand specifications.

 

 

 

 

data is being

For direct specification of link words:

 

 

 

 

written to or read

 

 

 

 

Use CX-Protocol to check the specified

 

 

 

 

from the I/O

 

 

 

 

range.

 

 

 

 

memory of the

 

 

 

 

 

 

 

 

 

 

 

CPU Unit.

 

 

 

 

 

 

 

 

 

 

4 Hex

ERR/

Protocol data

There is a code

Check the following items and correct

 

 

ALM:

syntax error

that cannot be

the problem.

 

 

Flashing

 

executed during

Check whether the total specified

 

 

 

 

protocol execution.

 

 

 

 

 

number of link words in the area (O1,

 

 

 

 

 

 

 

 

 

 

 

 

O2, I1, I2) exceeds 128.

 

 

 

 

 

The same area with link word

 

 

 

 

 

 

specification is used by both ports 1

 

 

 

 

 

 

and 2.

 

 

 

 

 

A write instruction with constant

 

 

 

 

 

 

specification is specified.

 

 

 

 

 

An EM Area read/write instruction is

 

 

 

 

 

 

specified as an interrupt notification.

 

 

 

 

 

There are more than 30 write

 

 

 

 

 

 

attributes set for one message.

 

 

 

 

 

The length of a send/receive message

 

 

 

 

 

 

is set to 0 bytes.

 

 

 

 

 

The length of a send/receive message

 

 

 

 

 

 

is longer than 127 bytes.

 

 

 

 

 

No messages are registered for matrix

 

 

 

 

 

 

reception.

 

 

 

 

 

Both RTS/CTS flow control and

 

 

 

 

 

 

Xon/Xoff flow control are set for the

 

 

 

 

 

 

same transmission line.

 

 

 

 

 

 

 

5 Hex

ERR/

Protocol macro

The PMCR

Check if the PMCR instruction was

 

 

ALM:

execution error

instruction was

executed during any one of the following

 

 

Flashing

during port

executed while the

processes.

 

 

 

initialization

port was being

While the serial communications port

 

 

 

 

initialized.

 

 

 

 

 

was being restarted.

 

 

 

 

 

 

 

 

 

 

 

While the serial communications mode

 

 

 

 

 

 

in the PC system setup of the Serial

 

 

 

 

 

 

Communications Board was being

 

 

 

 

 

 

modified using the STUP instruction.

 

 

 

 

 

While the serial communications mode

 

 

 

 

 

 

in the PC system setup of the Serial

 

 

 

 

 

 

Communications Board was being

 

 

 

 

 

 

modified using the Programming

 

 

 

 

 

 

Device.