V600/V620 ID Controller Protocol

Appendix M

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

 

 

storage words

 

 

 

 

 

 

Number of receive data words

 

+0

 

 

 

+1

 

 

Read data

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

+10

 

 

Read data

 

+11

 

 

Read data

 

 

 

 

 

~

~

 

 

 

 

 

+20

 

 

Read data

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

+71

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

~

~

+80

 

 

Read data

 

 

 

 

 

 

CH 1

CH 2

CH 8

Offset

Contents (data format)

Data

 

 

 

+0

Number of receive data

0002 to 0081

 

words (4 digits BCD)

 

 

 

 

+(10(N–1)+1) to

Read data (ASCII)

Number of read bytes stored in ASCII

+(10(N–1)+10)

 

 

 

 

 

N: Number of Heads

 

Note Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the receive data words.

Read (Hexadecimal/1) (Sequence No. 504)

This sequence is used when the number of Heads to be read from the Carrier is 1.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send +0

data

+1

+2

+3

+4

Number of send data words

(Undefined)

 

Unit No.

 

 

 

(Undefined)

 

Head CH No.

 

 

Leading address No.

 

 

(Undefined)

Read bytes

 

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0005 (fixed)

 

(4 digits BCD)

 

 

 

 

+1

Unit No. (2 digits BCD)

00 to 07 (CD1D)

 

 

00 to 15 (CAjA)

 

 

 

+2

R/W Head CH No. (1 digit BCD)

R/W Head CH 1 designation: 1

 

 

R/W Head CH 2 designation: 2

 

 

The CD1D must be set to 1.

 

 

 

+3

Leading address No.

0000 to FFFF

 

(4 digits Hexadecimal)

 

 

 

 

+4

Read bytes

01 to 7A (1 to 122 bytes)

 

(2 digits Hexadecimal)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

 

Number of receive data words

storage words

 

 

 

+1

 

Read data

 

 

 

 

 

 

 

+2

 

Read data

 

 

 

 

 

 

 

 

 

~

~

 

 

 

 

 

+61

 

Read data

 

 

 

 

378