3Z4L Laser Micrometer Protocol

Appendix K

 

 

 

Measurement Condition Set (4000-series) (Sequence No. 431)

This sequence sets measurement conditions. Conditions to be set can be selected by setting Yes/No flags.

Send Data Word Allocation (2nd Operand of PMCR)

First word of send data

+0

Number of send data words

 

 

 

 

 

+1

(Undefined)

 

 

 

 

 

+2

(Undefined)

 

 

 

 

 

 

+3

 

Decimal portion

 

 

 

 

 

+4

(Undefined)

 

Integer portion

 

 

 

 

 

+5

Sign

 

(Undefined)

 

 

 

 

 

+6

 

Decimal portion

 

 

 

 

+7

(Undefined)

 

Integer portion

 

 

 

 

+8

Sign

 

(Undefined)

 

 

 

 

+9

 

Decimal portion

 

 

 

 

+10

(Undefined)

 

Integer portion

 

 

 

 

+11

Sign

 

(Undefined)

 

 

 

+12

(Undefined)

 

 

 

 

 

 

+13

 

(Unused)

 

 

 

 

+14

 

(Unused)

 

 

 

 

+15

 

(Unused)

+16

(Undefined)

 

+17

(Undefined)

Data output timer (BCD 3 digits)

+18

(Undefined)

 

+19

 

0

 

 

+20

 

0

 

 

+21

 

0

 

 

+22

 

0

 

 

 

 

 

 

+23

 

0

 

 

 

 

 

 

+24

 

0

 

 

 

 

 

 

Segment number (SG) Measurement interval number (M)

Lower limit value (LL)

Upper limit value (LH)

Reference value (REF)

Analog output scale number (SCL)

Data output conditions (PR) (PRT)

Number of seconds for latch timer (RLT)

Setting Yes/No flags

340

Page 344
Image 344
Omron CQM1H-SCB41 operation manual Measurement Condition Set 4000-series Sequence No