Omron CQM1H-SCB41 operation manual 289

Models: CQM1H-SCB41

1 421
Download 421 pages 6 Kb
Page 294
Image 294

K3Tj Intelligent Signal Processor Protocol

Appendix I

Write Set Value (by Unit Number) (Sequence No. 302)

This sequence writes each set value (HH, H, L, LL).

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

send data

+1

+2

+3

+4

+5

Number of send data words

(Undefined)

Number of units

 

 

(Undefined)

Relevant unit No.

 

 

Operand

Set value

(Undefined)

Set value

~~

+122

+123

+124

+125

 

 

(Undefined)

Relevant unit No.

 

 

Operand

Set value

(Undefined)

Set value

Offset

Contents (data format)

 

 

Data

 

+0

Number of send data words

0006 to 0126

 

 

 

(4 digits BCD)

 

 

 

 

+1

Number of units

01 to 31

 

 

 

 

(2 digits BCD)

 

 

 

 

+2

Relevant unit No.

00 to 99

 

 

 

 

(2 digits BCD)

 

 

 

 

+3

Operand

4848 (“HH”),

4C4C (“LL”)

 

 

(ASCII 2 characters)

4820 (“H”),

 

4C20 (“L”)

 

+4 to

Set value

00000 to 99999

 

 

+5

(5 digits BCD)

Negative sign: F (most significant digit)

 

 

Example 12345

Example –1234

 

 

+4

2345

+4

1234

 

 

+5

0001

+5

000F

 

D

 

 

 

 

 

D

 

 

 

 

 

D

 

 

 

 

+124 to

Set value

Same as above

 

 

+125

(5 digits BCD)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Write Set Value HH (Continuous Units) (Sequence No. 303)

This sequence writes set value HH for continuous units.

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

Number of send data words

send data

+1

(Undefined)

Number of units

 

 

+2

Set value

 

+3

(Undefined)

Set value

 

~

 

~

+64

+65

Set value

(Undefined)

Set value

289