Number of units
Relevant unit No.
Relevant unit No.

K3Tj Intelligent Signal Processor Protocol

Appendix I

 

 

 

Reset (by Unit Number) (Sequence No. 300)

This sequence performs the same processing as when an input is received on the reset terminal.

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

send data

+1

+2

~

+33

Number of send data words

(Undefined)

(Undefined)

~

(Undefined)

Offset

Contents (data format)

Data

+0

Number of send data words

0003 to 0034

 

(4 digits BCD)

 

+1

Number of units

00 to 32

 

(2 digits BCD)

 

+2

Relevant unit No.

00 to 99

 

(2 digits BCD)

 

 

D

 

 

D

 

 

D

 

+33

Relevant unit No.

00 to 99

 

(2 digits BCD)

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.

Reset Control (Continuous Units) (Sequence No. 301)

This sequence performs reset control for continuous units.

Send Data Word Allocation (2nd Operand of PMCR)

First word of +0

send data

+1

Number of send data words

(Undefined)

Number of units

 

 

Offset

Contents (data format)

Data

 

 

 

+0

Number of send data words

0002

 

(4 digits BCD)

 

 

 

 

+1

Number of units

00 to 32

 

(2 digits BCD)

 

 

 

 

Receive Data Word Allocation (3rd Operand of PMCR)

None.