V500/V520 Bar Code Reader Protocol

Appendix J

 

 

 

BCR Function Read (V500) (Sequence No. 355)

This sequence reads the settings of functions in the Bar Code Reader.

Send Data Word Allocation (2nd Operand of PMCR)

None.

Receive Data Word Allocation (3rd Operand of PMCR)

Receive data

+0

Number of receive data words

storage words

 

 

 

 

+1

Operation mode

In-zone control

 

 

 

 

 

 

 

+2

Types of bar code

(Undefined)

 

 

 

 

 

 

+3

(Undefined)

Number of digits

 

+4

Modulus check

(Undefined)

 

+5

(Undefined)

Number of

Multistep

 

 

 

matches.

labels.

 

+6

Buzzer

Horizontal control

 

 

 

 

 

 

 

 

Offset

Contents (data format)

 

 

Data

 

 

 

+0

Number of receive data

0007 (fixed)

 

words (4 digits BCD)

 

 

 

 

 

 

 

 

+1

Operation mode

41

(‘A’) :

ONLINE

 

(ASCII 1 character)

42

(‘B’) :

ONLINE CONTROL

 

 

 

 

 

 

In-zone control

41

(‘A’) :

ON

 

(ASCII 1 character)

42

(‘B’) :

OFF

 

 

 

 

 

+2

Bar code type

41

(‘A’) :

JAN

 

(ASCII 1 character)

42

(‘B’) :

NW7 NORMAL

 

 

43

(‘C’) :

NW7 SMALL

 

 

44

(‘D’) :

NW7 HEX

 

 

45

(‘E’) :

CODE39 NORMAL

 

 

46

(‘F’) :

CODE39 ST/SP Output

 

 

47

(‘G’) :

2 of 5 (ITF)

 

 

48

(‘H’) :

CODE128

 

 

49

(‘I’) :

CODE93

 

 

4A (‘J’) :

2 of 5 (3BAR)

 

 

4B (‘K’) :

2 of 5 (5BAR)

 

 

 

 

+3

Number of digits

00 to 32

 

 

(2 digits BCD)

 

 

 

 

 

 

 

 

+4

Modulus check

41

(‘A’) :

No-check

 

(ASCII 1 character)

42

(‘B’) :

Modulus 10 (all bar codes)

 

 

43

(‘C’) :

Modulus 11 (except JAN)

 

 

44

(‘D’) :

Modulus 16 (NW7 only)

 

 

45

(‘E’) :

Modulus 43 (CODE39 only)

 

 

46

(‘F’) :

Modulus 47 (CODE93 only)

 

 

47

(‘G’) : Modulus 103 (CODE128 only)

 

 

 

 

+5

Number of matches

1 to 5

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

Multistep labels

1 to 4

 

 

(1 digit BCD)

 

 

 

 

 

 

 

 

+6

Buzzer

41

(‘A’) :

ON for normal read

 

(ASCII 1 character)

42

(‘B’) :

ON for no-read

 

 

43

(‘C’) :

OFF

 

 

 

 

 

 

Horizontal control mode

41

(‘A’) :

Normal (continuous rotating)

 

(ASCII 1 character)

42

(‘B’) :

In-zone startup

 

 

 

 

 

311

Page 315
Image 315
Omron CQM1H-SCB41 operation manual BCR Function Read V500 Sequence No